Abstract
Purpose Most computational fluid dynamics (CFD) studies on arteriovenous grafts (AVGs) adopt idealised geometries and simplified boundary conditions (BCs), potentially resulting in misleading conclusions when attempting to predict neointimal hyperplasia (NIH) development. Moreover, they often analyse a limited range of hemodynamic indices, lack validation, and fail to link the graft-altered hemodynamics with follow-up data. This study develops a novel patient-specific CFD workflow for AVGs using pathophysiological BCs. It validates the CFD results with patient medical data and assesses the co-localisation between CFD results and NIH regions at follow-up.
Methods Contrast-enhanced computed tomography angiography images were used to segment the patient’s AVG geometry. A uniform Doppler ultrasound (DUS)-derived velocity profile was imposed at the inlet, and three-element Windkessel models were applied at the arterial outlets of the domain. Transient, rigid-wall simulations were performed using the k-ω SST turbulence model. The CFD-derived flow waveform was compared with the patient’s DUS image to ensure validation. Turbulent kinetic energy (TKE), helicity and near-wall hemodynamic descriptors were calculated and linked with regions presenting NIH from a 4-month follow-up fistulogram.
Results In the analysed patient, areas presenting high TKE and balanced helical flow structures at baseline exhibit NIH growth at follow-up. Transverse wall shear stress index is a stronger predictor of NIH than other commonly analysed near-wall hemodynamic indices, since luminal areas subjected to high values greatly co-localise with observed areas of remodelling.
Conclusion This patient-specific computational workflow for AVGs could be applied to a larger cohort to unravel the link between altered hemodynamics and NIH progression in vascular access.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was funded by the University College London EPSRC Centre for Doctoral Training i4health [EP/S021930/1] and the Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS) [203145Z/16/Z]. We also acknowledge the BBRC International Institutional Awards University College London (IIA Tranche 1 UCL).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study received ethical approval from the Yale Institutional Review Board (approval number 2000032101).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability