ABSTRACT
Background One-time screening trials for atrial fibrillation (AF) have produced mixed results; however, it is unclear if there is a subset of individuals for whom screening would be effective. Identifying such a subgroup would support targeted screening.
Methods We conducted a secondary analysis of VITAL-AF, a randomized trial of one-time, single-lead ECG screening during primary care visits. We tested two approaches to identify a subgroup where screening is effective. First, we developed an effect-based model for heterogeneous screening effects using a T-learner. Specifically, we separately predicted the likelihood of AF diagnosis under screening and usual care conditions using LASSO, a penalized regression method. The difference between these probabilities was the predicted screening effect. Second, we used the CHARGE-AF score, a validated AF risk model, to test for a heterogeneous screening effect. We used interaction testing to determine if observed AF diagnosis rates in the screening and usual care groups differed when stratified by decile of the predicted screening effect and predicted AF risk.
Results Baseline characteristics were similar between the screening (n=15187) and usual care (n=15078) groups (mean age 74 years, 59% female). On average, screening did not significantly increase the AF diagnosis rate (2.55 vs. 2.30 per 100 person-years, rate difference 0.24, 95%CI -0.18 to 0.67). In the effect-based analysis, in the highest decile of predicted screening efficacy (n=3026), AF diagnosis rates were higher in the screening group (6.50 vs. 3.06 per 100 person-years, rate difference 3.45, 95%CI 1.62 to 5.28). In this group, the mean age was 84 years, 68% were female, and 55% had vascular disease. The risk-based analysis did not identify a subgroup where screening was more effective. Predicted screening effectiveness and predicted baseline AF risk were poorly correlated and demonstrated a U-shaped relationship (Spearman coefficient 0.13).
Conclusions In a secondary analysis of the VITAL-AF trial, we identified a small subgroup where one-time screening was associated with increased AF diagnoses using an effect-based approach. In this study, predicted AF risk was a poor proxy for predicted screening efficacy. These data caution against the assumption that high AF risk is necessarily correlated with high screening efficacy.
INTRODUCTION
The impetus to screen for atrial fibrillation (AF) is clear—AF is common and increases the risk of disabling strokes.1,2 Among those 65 years old, the lifetime incidence of atrial fibrillation is 33%.3 The goal of screening is to identify cases earlier than usual so stroke-preventive therapies, notably anticoagulation, can be used in appropriate patients to prevent ischemic stroke. However, randomized clinical trials (RCTs) of screening interventions have produced mixed results, and in 2022, the United States Preventive Services Task Force concluded that there was insufficient evidence to recommend routine screening for AF.4–8
One-time screening during routine clinical care is appealing because it is practical and is thought to identify individuals with high-burden AF.9,10 Nevertheless, all but one RCT testing one-time screening in traditional care settings (e.g., primary care offices) have failed to show that screening identifies more cases of AF in 6 to 12 months.5–8 However, it is unclear if there is a subset of people for whom screening is effective. While trials typically test for heterogeneity one subgroup at a time, newer methods allow for the examination of heterogeneity across multiple factors.11–15 This approach has been successfully applied in clinical decision models such as the Dual Antiplatelet Therapy (DAPT) score, which guides the duration of dual antiplatelet therapy after coronary stenting, and the PFO-Associated Stroke Causal Likelihood (PASCAL) score, which guides patient selection for PFO closure.16,17 Both models use multivariable prediction of treatment effect heterogeneity. Contemporary approaches also disentangle treatment effect and baseline disease risk.12 For example, screening might be less efficacious for those at high baseline risk since they may also have a high probability of being identified through routine clinical care. Identifying a subset of patients where screening is effective could support future screening strategies, including targeted screening trials.
Our goal was to determine if one-time AF screening during routine clinical care is effective in a subset of older adults. To accomplish this, we conducted a secondary analysis of the VITAL-AF RCT, which demonstrated that single-lead ECG screening for adults 65 years and older during their primary care office visits did not significantly change the rate of new AF diagnoses.18 In this secondary analysis, we aimed to identify a subset of people in whom screening is effective using “effect-based” and “risk-based” approaches.
METHODS
Study Design and Participants
This is a secondary, post-hoc analysis of the VITAL-AF trial to identify if AF screening is effective in a subset of individuals. The design and primary results from VITAL-AF have been published.18,19 In brief, VITAL-AF was a pragmatic, cluster-randomized trial that tested the efficacy of single-lead ECG screening during primary care visits compared to usual care. The trial randomized 16 primary care practices (8 to screening and 8 to usual care) in the Massachusetts General Hospital Primary Care-Based Research Network between July 2018 and October 2019. We did not adjust for the cluster-randomized design in this study because the intracluster correlation was low (0.0013). For these analyses, individuals 65 years and older without a prior diagnosis of AF presenting for a primary care appointment were included and participants with missing predictors were excluded (Supplemental Figure S1). All analyses were conducted on an intention-to-screen basis (i.e., group assignment was based on the patient’s first visit to a study practice during the study period). The Mass General Brigham Institutional Review Board approved the research protocol. Participants provided informed consent to participate. The study was considered minimal risk, and a waiver of documentation of informed consent was granted.
Procedure
As previously described, screening was conducted when consenting patients placed their fingers on a single-lead AliveCor KardiaMobile ECG device (AliveCor Inc, Mountain View, CA). The screening resulted in one of five possible results, “Possible AF,” “Normal,” “Unclassified,” “No analysis (Unreadable),” and “Patient Declined Screening.” All subsequent clinical management was determined by primary care clinicians, including follow-up 12-lead ECGs. Independent cardiologists reviewed all AliveCor tracings within 7 days and notified primary care clinicians if a prespecified actionable rhythm was identified.
Outcome
The primary outcome was an adjudicated incident AF diagnosis. Each clinical practice was enrolled for 12 months; participants were followed until the primary care practice to which they belonged completed participation. Thus, follow-up time was measured from each participant’s first visit date until the date their primary care practice completed participation or death, whichever came first. Potentially new AF diagnoses were identified from the electronic medical record using the same approach in both study arms by a centralized data repository.20 Specifically, individuals with an International Classification of Diseases, 10th Revision code for atrial fibrillation or flutter or a 12-lead ECG with atrial fibrillation or flutter in the diagnostic statement were identified. These potential new AF diagnoses were then adjudicated by 2 research nurses with a cardiologist unaffiliated with the study resolving differences. The committee adjudicated events as “incident,” “prevalent,” or “not AF.”21
Predictors
We obtained patient characteristics from the electronic medical record, including demographics, medical diagnoses, medication use, physiological measures, and prior health use. We used measures obtained on the participant’s first visit date or the value most immediately prior. Candidate predictors were chosen because of their association with AF, cardiovascular disease, or health care utilization. Demographics included age, sex, and English language preference. Medical diagnoses included hypertension, myocardial infarction, coronary artery disease, diabetes, congestive heart failure, prior stroke, vascular disease, anemia, bleeding history, chronic kidney disease, and tobacco smoking. Medications were grouped into one of the following categories: oral anticoagulants, rate control medications, antihypertensives, or antiarrhythmic medications. Physiological measures include systolic blood pressure, diastolic blood pressure, heart rate, height, and weight. Healthcare utilization measures included 12 lead ECGs in the prior year, indwelling cardiac rhythm device implanted in the prior 3 years (i.e., permanent pacemaker, implantable cardioverter defibrillator, or implantable loop recorder), and the number of primary care visits in the prior year.
Effect-based approach to heterogeneity
Our objective was to identify individuals for whom screening is effective by measuring the heterogeneity of AF screening using an effect-based approach.12 To do so, we estimated the effect of screening for each individual given their observed characteristics, i.e., the conditional average screening effect.22 Specifically, we used a T-learner wherein, for each individual, we estimated the probability of the outcome (i.e., new AF diagnosis) had they been randomized to screening and, separately, had they been randomized to usual care.23
Operationally, we first estimated the likelihood of the outcome conditional on being randomized to the screening. Using just the participants randomized to the screening practices, we fit a generalized linear model of the outcome as a function of all the predictors described above using a Poisson distribution offset by the log of the follow-up time to account for differential follow-up time. This model was fit using the least absolute shrinkage and selection operator (LASSO), which we used to perform variable selection and regularization.24 Then, we applied this model to the usual care participants to estimate the likelihood of the outcome had they been randomized to the screening. Next, we estimated the likelihood of the outcome conditional on being randomized to screening within the screening arm. To limit bias, we estimated the likelihood of the outcome within the intervention group using leave-one-out cross-validation.25 That is, the likelihood of the outcome for an individual intervention participant was estimated using a model that was fit with all intervention observations except that individual. These models were also fit using LASSO.
We repeated the same procedure to estimate the likelihood of the outcome under usual care. This process resulted in two predicted probabilities of AF diagnosis for each participant— one had they been screened and one under usual care. The difference between these two is the conditional average screening effect. We then tabulated the observed outcome rate by randomization arm stratified by decile of conditional average screening effect.
Risk-based approach to heterogeneity
In a second approach, we measured the heterogeneity of AF screening using a risk-based approach. We used the CHARGE-AF risk score to estimate the baseline risk of developing AF.26 CHARGE-AF is a risk model developed in the Atherosclerosis Risk in Communities study, Cardiovascular Health Study, and the Framingham Heart Study to predict incident AF. It uses age, race, height, weight, blood pressure, current smoking, use of antihypertensive medication, diabetes, myocardial infarction history, and heart failure as predictors. The CHARGE-AF model has been externally validated.27 Because CHARGE-AF was developed externally, its performance may be disadvantaged compared to the internally developed effect score. In a sensitivity analysis, we determined if an internally optimized AF risk model performed better than the CHARGE-AF model.
Testing for heterogeneity
We assessed heterogeneity by testing the interaction between the randomization arm and the predicted screening effect. Specifically, we fit a generalized linear model where the outcome of new AF diagnosis was a function of the randomization arm, decile of predicted screening effect, and the interaction between the two. The model was fit using a Poisson distribution offset by the log of the follow-up time to account for differential follow-up time. We tested the statistical significance of the interaction using the likelihood ratio test. For visual representation we plotted the observed outcome rate by randomization arm, stratified by decile of screening effect. We repeated this procedure to test for heterogeneity by predicted AF risk.
Patient characteristics by predicted effect and predicted risk
We used heatmaps to visualize participant characteristics by decile of predicted screening effect and predicted AF risk. We color-coded characteristics by their z-transformed value, where the darkest and lightest shade represent the highest and lowest value of a given patient characteristic, respectively.
Correlation of predicted effect and predicted risk
To determine the correlation between the conditional average screening effect and baseline risk, we plotted the percentile of predicted screening effectiveness against the percentile of predicted AF risk. We described the relationship using a locally estimated best-fit line with a span of 0.75.
RESULTS
Average effect of screening
We present the baseline characteristics of 30265 study participants in Table 1. In 10333 person-years of follow-up, 238 people in the usual care group were diagnosed with atrial fibrillation (2.30 per 100-person years). In 10284 person-years of follow-up, 262 people in the screening group were diagnosed with atrial fibrillation (2.55 per 100 person-years). These rates were not statistically different (rate difference 0.24 per 100 person-years, 95%CI -0.18 to 0.67).
Model performance
The constituent models used to estimate the effect-based score discriminated well. The model to predict AF diagnosis under usual care and the model to predict AF diagnosis in screening both had a c-statistic of 0.73 and were well calibrated (Supplemental Figures S2 and S3). The CHARGE-AF risk model also discriminated well; it had a c-statistic of 0.74 in both the control and intervention arms (Supplemental Figures S4 and S5).
Effect-based approach to screening heterogeneity
Participants whose predicted screening effect fell into the highest decile (estimated by the effect-based model) had a statistically significant increase in AF diagnoses due to their primary care practice being randomized to the screening arm (interaction p-value 0.038).
In Figure 1, we display the distribution of observed absolute rate differences in AF diagnosis in each decile of predicted screening effect. In the decile where screening was predicted to be the most efficacious, the observed rate of new atrial fibrillation diagnosis was higher in those randomized to intervention compared to those randomized to usual care (6.50 vs. 3.06 per 100 person-years, rate difference 3.45 per 100 person-years, 95% CI 1.62 to 5.28). In the remaining 9 deciles, the observed rates of AF diagnosis in the intervention and usual care groups were not significantly different. In a sensitivity analysis where we evaluated the screening effect model in a continuous fashion suggested a dose-response (Supplemental Figure S6).
Risk-based approach to screening heterogeneity
The risk model (i.e., CHARGE-AF) did not identify a subgroup in which one-time AF screening was effective (interaction p-value 0.46). In Figure 2, we display the distribution of observed absolute rate difference in AF diagnosis in each decile of predicted AF risk. The observed rates of AF diagnosis in the intervention and screening groups were not significantly different in any decile of predicted AF risk. In the highest risk decile, AF diagnosis rates were numerically higher in the screening (7.89 vs 5.77 per 100 person-years), but the difference was not statistically significant (rate difference 2.12, 95%CI -0.05 to 2.49). In a sensitivity analysis, we determined that an internally optimized risk model also did not identify a subgroup where screening was effective (Supplemental Figure S7).
Patient characteristics of effective screening groups
In Figure 3, we display the patient characteristics by decile of screening effectiveness. Patients with an indwelling cardiac rhythm device placed in the prior 3 years, higher BMI, and greater number of PCP visits in the prior year were overrepresented in the lower deciles of screening effectiveness. Rate control medications, high systolic blood pressure, and smoking were more common in the highest deciles of screening effectiveness. Several characteristics displayed a U-shaped relationship, such as age, vascular disease, and congestive heart failure.
Patient characteristics of risk groups
In Figure 4, we display the patient characteristics by decile of risk estimated using the CHARGE-AF score. Black participants, Hispanic participants, and women were overrepresented in the lower deciles of risk. As expected, predictors used to calculate the CHARGE-AF score were more common in higher risk deciles, including older age; higher height, weight, or blood pressure; smoking history; White racial identity; antihypertensive medication use; or diagnosis of diabetes, CHF, or prior MI. Among variables not directly used to calculate CHARGE-AF, we find that patients in the highest risk deciles were more likely to have had an indwelling cardiac rhythm device placed in the prior 3 years, male sex, chronic kidney disease, and anemia.
Relationship between predicted risk and predicted screening effect
The predicted screening effect and the predicted risk of new AF have a non-monotonic relationship. In Figure 5, we show a scatterplot of the relationship between the percentile of AF screening effectiveness against the percentile of baseline AF risk measured by the CHARGE-AF score. Predicted screening effectiveness and predicted baseline risk were poorly correlated (Spearman coefficient 0.13). A locally estimated best-fit line demonstrated a U-shaped relationship—the predicted risk of AF was high among both those with low and high predicted screening effectiveness.
DISCUSSION
In this secondary analysis of the VITAL-AF randomized trial, we identified a small subgroup in whom one-time screening was effective using an effect-based modeling approach. In the subset where screening appears to be effective, individuals are often in the 80s, have hypertension and vascular disease, are seen less often by their PCP and are women—a complete phenotype is available online.28 Despite a trend toward greater efficacy in the highest-risk group, a risk-based approach did not identify a subgroup for whom screening was statistically more effective. We also determined that predicted risk and predicted screening effectiveness were not well correlated. This suggests that when screening for AF with a brief one-time screen, predicted risk is an inadequate surrogate for predicted screening effectiveness.
An inspection of patient characteristics provides insights into the value of an effect-based approach. The 2% of study participants with an indwelling cardiac rhythm device (i.e., permanent pacemaker, implantable cardioverter defibrillator, or implantable loop recorder) are an important negative control. Because of the pragmatic study design, people with indwelling cardiac rhythm devices were included; however, because they monitor for AF continuously, mechanistically, one-time office-based AF should not be effective for people with such devices.
In this study, the effect-based model appropriately concludes that screening would not be effective in people with indwelling cardiac rhythm devices. On the other hand, the risk model classified individuals with indwelling cardiac rhythm devices as among the highest risk of developing AF. Thus, using risk to guide screening would inappropriately prioritize individuals with indwelling cardiac rhythm devices. This example highlights how an effect-based approach can identify people for whom screening is effective, irrespective of their risk of AF.
The results of this study can inform future efforts at targeting screening in at least three ways. First, this study identifies a subgroup in which screening appears particularly effective. While VITAL-AF, D2AF, and Morgan & Mant found no average benefit of one-time screening, SAFE found an increase in AF diagnosis rate of 0.55% over 12 months.6–8,18 In our current study, we identified a subgroup in whom screening was 3 to 10 times more effective than the average effect observed in SAFE. To demonstrate the value of one-time screening, future trials should consider targeting screening to the high-efficacy phenotype. There are shortcomings to this approach, namely that the subset in whom screening is effective is small, and any targeting approach creates implementation challenges. To facilitate the identification of high-effectiveness patients, we have published a supplemental online code that can be incorporated into electronic medical records or screening trials.28 Second, our findings that AF risk and screening effect are not well correlated indicate that screening trials targeting high-risk individuals may not be fruitful. Indeed, multiple trials are underway to test the value of screening by enrolling high-risk individuals.32–35 Third, our findings highlight the potential for inequity using a risk-based approach, particularly a risk equation like CHARGE-AF that uses race as a predictor. In this study, while non-white and female participants were concentrated in the low-risk deciles, both groups were more evenly distributed across the spectrum of screening efficacy. Thus, well-meaning efforts to target screening to high-risk individuals may widen disparities.
There are a few possible reasons for the observed discordance between AF risk and screening effect. First, the effect model may identify people who do not fit physicians’ heuristic for AF, so-called representation bias.29,30 For example, those in the high-efficacy group were more likely to be non-white women with a non-English language preference. These same characteristics were more prevalent in low-risk groups. Second, screening efficacy may be a function of healthcare access and connectedness.31 The average number of PCP visits in the prior year was lowest in the high-screening efficacy group. This indicates that individuals who are often seen by their PCP may benefit less from one-time screening despite being at high risk for developing AF, presumably because physicians have an increased opportunity to detect heart rhythm abnormalities. Since the degree of access to “usual care” varies, one-time screening may be more effective for people with limited healthcare access. Third, it is possible that those in the high-efficacy group are more likely to develop asymptomatic AF, a hypothesis that could not be tested with the available data.
Finally, this study adds to the ongoing development of effect-based approaches to measuring the heterogeneous effect of cardiovascular interventions.12–15 For the treatment and prevention of many cardiovascular conditions, like statins to prevent atherosclerotic heart disease and anticoagulants to prevent stroke in AF, clinicians are asked to identify a subset of people for whom treatment is particularly effective.36,37 The conventional approach has been to model risk—that is, to develop an outcome model in untreated individuals and assume that this risk is tightly correlated with the effectiveness of the intervention, the true value of interest. This study demonstrates the vulnerability of this assumption. Prior studies have shown that risk-based models can effectively measure variation in treatment effect.38,39 This study suggests that, when possible, both risk-based and effect-based approaches should be tested when determining if an intervention should be targeted to a subset of individuals.
Our study design and data source have important limitations. First, the high-efficacy subgroup identified in this study needs to be externally validated. While we took caution when identifying the subgroup (i.e., using regularized regression models and leave-one-out cross-validation), external validation in a separate RCT is necessary to test the robustness of the findings. Second, this analysis was not pre-specified in the statistical analysis plan of the main trial. Thus, the results should be regarded as exploratory and hypothesis-generating. Third, screening for atrial fibrillation is important in so far as it prevents ischemic strokes. While one-time screening tends to identify individuals with high-burden AF, the full study was not powered to detect the effect of screening on strokes and bleeding.
Prior trials of one-time screening have demonstrated mixed results. In a secondary analysis, we identified a small subgroup where one-time screening was associated with increased AF diagnoses using an effect-based modeling approach. Also, we determined that risk is a poor proxy for the effectiveness of AF screening. These data caution against the assumption that high risk is necessarily correlated with high efficacy. Future screening efforts should focus on people for whom screening is projected to be most effective.
Data Availability
Data are not publicly available.
Author contributions
Dr. Shah had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis. All authors listed have contributed sufficiently to the project to be included as authors, and all those who are qualified to be authors are listed in the author byline.
Conflict of Interest Disclosure
Dr. Shah reported funding from the National Institute on Aging/National Institutes of Health related to the conduct of this study (noted below). Dr. Atlas has received sponsored research support from Bristol Myers Squibb / Pfizer and American Heart Association (18SFRN34250007). Dr. Atlas has consulted for Boehringer Ingelheim, Bristol Myers Squibb, Pfizer, and Fitbit. Dr. Ashburner is supported by NIH grant K01HL148506, American Heart Association 18SFRN34250007, and has received sponsored research support from Bristol Myers Squibb / Pfizer. Dr. Ellinor is supported by grants from the National Institutes of Health (R01HL092577, R01HL157635), by a grant from the American Heart Association (18SFRN34110082, 961045), and by a grant from the European Union (MAESTRIA 965286). Dr. Ellinor has received sponsored research support from Bayer AG, Novo Nordisk, Pfizer, Bristol Myers Squibb and IBM; he has also served on advisory boards or consulted for Bayer AG. Dr. Lubitz is an employee of Novartis. Dr. Lubitz was previously supported by NIH grants R01HL139731 and R01HL157635, and American Heart Association 18SFRN34250007. Dr. Lubitz received sponsored research support from Bristol Myers Squibb, Pfizer, Boehringer Ingelheim, Fitbit, Medtronic, Premier, and IBM, and has consulted for Bristol Myers Squibb, Pfizer, Blackstone Life Sciences, and Invitae. Dr. Singer is supported, in part, by the Eliot B. and Edith C. Shoolman Fund of Massachusetts General Hospital. Dr. Singer receives research support from Bristol Myers Squibb-Pfizer and has received consulting fees from Bristol Myers Squibb, Fitbit (Google), Medtronic, and Pfizer. Dr. McManus reports having received compensation from Fitbit for serving on the Fitbit Heart Study Advisory Board, from the Heart Rhythm Society for service as Editor, from Avania and NAMSA for serving on Data and Safety Monitoring Boards and has received non-compensatory study support from Apple Computer, Fitbit, and Care Evolution. The remaining authors have nothing to disclose.
Funding
This analysis was funded by the NIA (K76AG074919). The VITAL-AF study was an investigator-initiated study funded by the Bristol Myers Squibb/Pfizer Alliance.
Role of the Funder/Sponsor
The funders had no role in the design and conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; and decision to submit the manuscript for publication.
SUPPLEMENTAL MATERIAL
ACKNOWLEDGMENTS
Footnotes
Corrected grammar mistakes in the method section. Clarified that ICDs mean indwelling cardiac devices.