Abstract
High detail and fast magnetic resonance imaging (MRI) sequences are highly demanded in clinical settings, as inadequate imaging information can lead to diagnostic difficulties. MR image super-resolution (SR) is a promising way to address this issue, but its performance is limited due to the practical difficulty of acquiring paired low- and high-resolution (LR and HR) images. Most existing methods generate these pairs by down-sampling HR images, a process that often fails to capture complex degradations and domain-specific variations. In this study, we propose a domain-distance adapted SR framework (DDASR), which includes two stages: the domain-distance adapted down-sampling network (DSN) and the GAN-based super-resolution network (SRN). The DSN incorporates characteristics from unpaired LR images during down-sampling process, enabling the generation of domain-adapted LR images. Additionally, we present a novel GAN with enhanced attention U-Net and multi-layer perceptual loss. The proposed approach yields visually convincing textures and successfully restores outdated MRI data from the ADNI1 dataset, outperforming state-of-the-art SR approaches in both perceptual and quantitative evaluations. Code is available at https://github.com/Yaolab-fantastic/DDASR.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
ADNI data collection and sharing for this project is funded by the Alzheimer's Disease Metabolomics Consortium (National Institute on Aging R01AG046171, RF1AG051550 and 3U01AG024904-09S4). For private HR data, informed consent has been obtained from all participants and the research ethics committees or institutional review boards approved the data collection.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study used (or will use) ONLY openly available human data that were originally located at: https://adni.loni.usc.edu.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
shan.cong.yao{at}hrbeu.edu.cn; cuikailong.yao{at}hrbeu.edu.cn; luohaoran.yao{at}hrbeu.edu.cn;
yangyuzun{at}hrbeu.edu.cn
zhouyang094{at}126.com; wangxinxin{at}hrbmu.edu.cn
The affiliations of the first author, second author, and corresponding author have been modified.
Data Availability
All data produced in the present work are contained in the manuscript