Abstract
EPA recommends DIY air cleaners for temporary use during wildfires, and a recent EPA study reported inconsistent usage in homes due to excessive noise. Questions also remain about wear and tear including how long filters retain their filtration properties and need to be replaced. Herein we report real-world experience from daily usage of 47 HEPA and 60 DIY air cleaners in a California elementary school during the academic school year from spring 2021 through fall of 2022 across 16 classrooms, a library, an auditorium, a lunchroom, and in a hallway. Three to six purifiers were needed in classrooms to meet California (CDPH) recommended 6 to 12 air changes per hour (ACH) for prevention of aerosol transmission of COVID-19 in classrooms. Teachers reported noise generated by DIY purifiers on lowest fan speed as acceptable for classroom use. Filtration efficiency at 0.3 μm (most penetrating particle size) for DIY air cleaners with 5” MERV 16 filters used in the classrooms averages 77% after six months compared to 92% for newly installed filters. Portable air cleaners (HEPA and DIY) averaged and estimated 10 ACH (6-15 ACH) across the 16 classrooms demonstrating feasibility and unit economics of meeting CDPH targets per classroom for $200-$650 with DIY versus $600-$12,000 with the HEPA models used. In one 9000 cubic foot classroom with 7 air purifiers, air exchange rate was measured using ambient aerosols at 18 ACH from air purifiers (within 20% of ACH estimated based on CADR of purifiers) and 7 ACH from HVAC for a combined total of 25 ACH. The procedure using ambient aerosols to verify ACH from portable air cleaners and HVAC can be the basis for ACH certification or verification without generating aerosol contaminants (e.g. salt water, smoke, tracers) which may be unsafe or disallowed in schools.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Data Availability
All data produced in the present study are available upon reasonable request to the authors