There is an immediate need for efficient networks to detect and control novel/emerging bioaerosol threats. In 2022, the Pentagon Force Protection Agency (PFPA) found detection of emerging bioaerosol threats to be “not feasible for daily operations” due to cost of reagents used for metagenomics, cost of sequencing instruments, and time/cost for labor (subject matter expertise) to analyze bioinformatics. If the Pentagon experiences these operational difficulties, they may also extend to many of the 280,000 buildings (2.3 billion square feet) at 5000 secure US DoD military sites, 250 US Navy ships, and beyond in civilian buildings around the world. These economic barriers can still be addressed in a threat-agnostic manner by dynamically pooling samples from a network of dry filter units (DFUs) to detect spatio-temporally correlated “spikes” in novel pathogen concentrations, termed Spike Triggered Virtualization (STV). In STV, pooling and sequencing depth are automatically modulated in the next cycle in response to novel potential biothreats in the sequencing output of the previous sequencing cycle. By running at a high pooling factor and lower depth unless triggered by a potential pathogen spike, average daily and annual cost per DFU can be reduced by one to two orders of magnitude depending on chosen trigger thresholds. Artificial intelligence (AI) can further enhance sensitivity of STV triggers. Risk of infection remains during the 12-24 hour window between a bioaerosol incident and its detection, but can in some cases be reduced by 80% or potentially more with high-speed indoor air cleaning exceeding 10 air changes per hour (10 ACH) similar to passenger airplanes (Airbus A319, A321 and a Boeing 737-Max8/9) that were tested in flight. Costs of 4 ACH or higher are expected to rise non-linearly with ACH using central HVAC systems and be cost-prohibitive. Whereas 10 ACH or more can be achieved economically by recycling the air in rooms with low-noise, portable air filtration systems tested herein for which costs scale linearly with ACH. For typical ceiling heights (< 10 ‘), the cost per square foot cost for low-noise air filtration exceeding 10 ACH was found to be approximately $0.5 to $1 for Do-It-Yourself (DIY) and $2 to $5 for HEPA.
Competing Interest Statement
I am not associated with any of the manufacturers mentioned in this research. Inventor on US patent #11555764.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Email: sri{at}patientknowhow.com
Discussion / summary of Pentagon-DHS request for information (RFI) issued on March 2, 2023 Discussion of Spatio-Temporally correlated spikes and supporting dataset from from FDA
Data Availability
All data produced in the present study are available upon reasonable request to the authors