ABSTRACT
Regular monitoring of common physiological signs, including heart rate, blood pressure, and oxygen saturation, can be an effective way to either prevent or detect many kinds of chronic conditions. In particular, cardiovascular diseases (CVDs) are a worldwide concern. According to the World Health Organization, 32% of all deaths worldwide are from CVDs. In addition, stress-related issues cost $190 billion in healthcare costs per year. Currently, contact devices are required to extract most of an individual’s physiological information, which can be uncomfortable for users and can cause discomfort. However, in recent years, remote photoplethysmography (rPPG) technology is gaining growing interest, which enables contactless monitoring of the blood volume pulse signal using a regular camera, and ultimately can provide the same physiological information as a contact device. In this paper, we propose a benchmark comparison using a new multimodal database consisting of 56 subjects where each subject was submitted to three different tasks. Each subject wore a wearable device capable of extracting photoplethysmography signals and was filmed to allow simultaneous rPPG signal extraction. Several experiments were conducted, including a comparison between information from contact and remote signals and stress state recognition. Results have shown that in this dataset, rPPG signals were capable of dealing with motion artifacts better than contact PPG sensors and overall had better quality if compared to the signals from the contact sensor. Moreover, the statistical analysis of the variance method had shown that at least two HRV features, NNi 20 and SAMPEN were capable of differentiating between Stress and Non-Stress states. In addition, three features, IBI, NNi 20, and SAMPEN were capable of differentiating between tasks relating to different levels of difficulty. Furthermore, using machine learning to classify a ‘stressed’ or ‘unstressed’ state, the models were able to achieve an accuracy score of 83.11%.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
None
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Researchers interested in access to the data may contact Nikhil Sehgal at nikhil.sehgal@vastmindz.com, also see https://vastmindz.com/contact/. The authors will assist with any negotiable data use agreements and gain access to the data for any replication efforts following publication.
Abbreviations
- AI
- Artificial Intelligence
- ANOVA
- Analysis of Variance
- ANN
- Artificial neural network
- ANS
- Autonomic Nervous System
- BVP
- Blood Volume Pulse
- CVD
- Cardiovascular diseases
- HRV
- Heart Rate Variability
- POS
- Plane-Orthogonal-to-Skin
- PPG
- photoplethysmography
- rPPG
- Remote Photoplethysmography
- SNR
- signal-to-noise ratio
- WHO
- World Health Organization