Abstract
Background Rapid detection of infectious individuals is essential in stopping the further spread of SARS-CoV-2. Although rapid antigen test is not as sensitive as the gold standard RT-PCR, the time to result is decreased by day(s), strengthening the effectiveness of contact tracing.
Methods The Roche/SD Biosensor lateral flow antigen rapid test was evaluated in a mild symptomatic population at a large drive through testing site. A second nasopharyngeal swab was directly tested with the rapid test on site and results were compared to RT-PCR and virus culture. Date of onset and symptoms were analysed using data from a clinical questionnaire.
Results We included 970 persons with complete data. Overall sensitivity and specificity were 84.9% (CI95% 79.1-89.4) and 99.5% (CI95% 98.7-99.8) which translated into a positive predictive value of 97.5% (CI95% 94.0-99.5) under the current regional PCR positivity of 19.2%. Sensitivity for people with high loads of viral RNA (ct <30, 2.17E+05 E gene copy/ml) and who presented within 7 days since symptom onset increased to 95.8% (CI95% 90.5-98.2). Band intensity and time to result correlated strongly with viral load thus strong positive bands could be read before the recommended time. Around 98% of all viable specimen with ct <30 were detected successfully indicating that the large majority of infectious people can be captured with this test.
Conclusion Antigen rapid tests can detect mildly symptomatic cases in the early phase of disease thereby identifying the most infectious individuals. Using this assay can have a significant value in the speed and effectiveness of SARS-CoV-2 outbreak management.
Summary
People with early onset and high viral load were detected with 98.2% sensitivity.
97% of individuals in which virus could be cultured were detected by the rapid test.
This test is suitable to detect mild symptomatic cases.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was partly supported by H2020 project RECoVer [grant number 101003589].
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The medical research ethics committee (MREC) of Utrecht decided the study was not subject to the Medical Research Involving Human Subjects Act (WMO) and did not require full review by an accredited MREC (protocol number 20-606/C).
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
all data is available