Abstract
The standard RT-PCR assay for COVID-19 is laborious and time-consuming, limiting the availability of testing. Rapid antigen-detection tests are faster and less expensive; however, the reliability of these tests must be validated before they can be used widely. The objective of this study was to determine the reliability of the PanbioTM COVID-19 Ag Rapid Test Device (PanbioRT) (Abbott) for SARS-CoV-2 in nasopharyngeal swab specimens. This was a prospective multicenter study in ten Spanish university hospitals of patients from hospital units with clinical symptoms or epidemiological criteria for COVID-19. Patients whose onset of symptoms or exposure was more than 7 days earlier were excluded. Two nasopharyngeal exudate samples were taken to perform the PanbioRT and a diagnostic RT-PCR test. Among the 958 patients studied, 359 (37.5%) were positive by RT-PCR and 325 (33.9%) were also positive by the PanbioRT. Agreement was 95.7% (kappa score: 0.90). All 34 false-negative PanbioRT results were in symptomatic patients, with 23.5% of them at 6–7 days since the onset of symptoms and 58.8% presenting CT >30 values for RT-PCR, indicating a low viral load. Overall sensitivity and specificity for the PanbioRT were 90.5% and 98.8%, respectively. The PanbioRT provides good clinical performance as a point-of-care test, with even more reliable results for patients with a shorter clinical course of the disease or a higher viral load. While this study has had a direct impact on the national diagnostic strategy for COVID-19 in Spain, the results must be interpreted based on the local epidemiological context.
- COVID-19
- rapid antigen-detection test
- SARS-CoV-2
Competing Interest Statement
RC has participate in educational programs organized by Abbot. The other authors have none to declare.
Funding Statement
This study did not receive public or private funds.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics Committee for Healthcare (CEAS) of Hospital Clinico San Carlos
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
‡ Members of the Group are listed in Acknowledgements
Paper in collection COVID-19 SARS-CoV-2 preprints from medRxiv and bioRxiv
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.