Background A low first-pass success rate of radial artery cannulation was obtained when using the conventional palpation technique(C-PT) or ultrasound-guided techniques, we therefore evaluate the effect of a modified long-axis in-plane ultrasound technique (M-LAINUT) in guiding radial artery cannulation in adults.
Methods We conducted a prospective, randomized and controlled clinical trial of 288 patients undergoing radial artery cannulation. Patients were randomized 1:1 to M-LAINUT or C-PT group at fujian medical university union hospital between 2017 and 2018. Radial artery cannulation was performed by three anesthesiologists with different experience. The outcome was the first and total radial artery cannulation success rates, the number of attempts and the cannulation time.
Results 285 patients were statistically analyzed. The success rate of first attempt was 91.6% in the M-LAINUT group (n=143) and 57.7% in the C-PT group (n=142; P<0.001) (odds ratio, 7.9; 95% confidence interval, 4.0-15.7). The total success rate (≤5 min and ≤3 attempts) in the M-LAINUT group was 97.9%, compared to 84.5% in the palpation group (p <0.001) (odds ratio, 8.5; 95% confidence interval, 2.5-29.2). The total cannulation time was shorter and the number of attempts was fewer in the M-LAINUT group than that in the C-PT group (p <0. 05).
Conclusion Modified long-axis in-plane ultrasound-guided radial artery cannulation can increase the first and total radial artery cannulation success rates, reduce the number of attempts and shorten the total cannulation time in adults.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
ChiCTR-IOR-17011474
Clinical Protocols
http://www.chictr.org.cn/index.aspx
Funding Statement
This work was supported in part by Fujian Province Science and Technology Innovation Joint Fund Project of China(2017Y9008) and the National Natural Science Foundation of China (Grant number: 81641038). They were not involved in research design, collection, data analysis, or approved to submit articles for publication.
Author Declarations
All relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
Any clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.
Yes
Data Availability
The data used to support the findings of this study are included within the article.
Abbreviations
- ICU
- intensive care unit
- M-LAINUT
- modified long-axis in-plane ultrasound technique
- C-PT
- the conventional palpation technique
- CFM
- color doppler mode
- OR
- odds ratio
- CI
- confidence interval
- MAP
- mean arterial pressure
- BMI
- body mass index
- PVD
- peripheral vascular disease
- CA
- clinical anesthetists
- SD
- standardized difference