PT - JOURNAL ARTICLE AU - Wang, Jiebo AU - Lai, Zhongmeng AU - Weng, Xianfeng AU - Lin, Yong AU - Wu, Guohua AU - Su, Jiansheng AU - Huang, Qijian AU - Zeng, Jian AU - Liu, Junle AU - Zhao, Zisong AU - Yan, Ting AU - Zhang, Liangcheng AU - Zhou, Linying TI - Modified Long-Axis In-Plane Ultrasound Technique Versus Conventional Palpation Technique For Radial Arterial Cannulation: A Prospective Randomized Controlled Trial AID - 10.1101/19001586 DP - 2019 Jan 01 TA - medRxiv PG - 19001586 4099 - http://medrxiv.org/content/early/2019/07/20/19001586.short 4100 - http://medrxiv.org/content/early/2019/07/20/19001586.full AB - Background A low first-pass success rate of radial artery cannulation was obtained when using the conventional palpation technique(C-PT) or ultrasound-guided techniques, we therefore evaluate the effect of a modified long-axis in-plane ultrasound technique (M-LAINUT) in guiding radial artery cannulation in adults.Methods We conducted a prospective, randomized and controlled clinical trial of 288 patients undergoing radial artery cannulation. Patients were randomized 1:1 to M-LAINUT or C-PT group at fujian medical university union hospital between 2017 and 2018. Radial artery cannulation was performed by three anesthesiologists with different experience. The outcome was the first and total radial artery cannulation success rates, the number of attempts and the cannulation time.Results 285 patients were statistically analyzed. The success rate of first attempt was 91.6% in the M-LAINUT group (n=143) and 57.7% in the C-PT group (n=142; P<0.001) (odds ratio, 7.9; 95% confidence interval, 4.0-15.7). The total success rate (≤5 min and ≤3 attempts) in the M-LAINUT group was 97.9%, compared to 84.5% in the palpation group (p <0.001) (odds ratio, 8.5; 95% confidence interval, 2.5-29.2). The total cannulation time was shorter and the number of attempts was fewer in the M-LAINUT group than that in the C-PT group (p <0. 05).Conclusion Modified long-axis in-plane ultrasound-guided radial artery cannulation can increase the first and total radial artery cannulation success rates, reduce the number of attempts and shorten the total cannulation time in adults.Competing Interest StatementThe authors have declared no competing interest.Clinical TrialChiCTR-IOR-17011474Clinical Protocolshttp://www.chictr.org.cn/index.aspxFunding StatementThis work was supported in part by Fujian Province Science and Technology Innovation Joint Fund Project of China(2017Y9008) and the National Natural Science Foundation of China (Grant number: 81641038). They were not involved in research design, collection, data analysis, or approved to submit articles for publication.Author DeclarationsAll relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesAny clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.YesI have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.YesThe data used to support the findings of this study are included within the article.ICUintensive care unitM-LAINUTmodified long-axis in-plane ultrasound techniqueC-PTthe conventional palpation techniqueCFMcolor doppler modeORodds ratioCIconfidence intervalMAPmean arterial pressureBMIbody mass indexPVDperipheral vascular diseaseCAclinical anesthetistsSDstandardized difference