Abstract
Introduction Cystic fibrosis (CF) is characterized by increased ventilation inhomogeneity (VI), as measured by multiple breath washout (MBW), from infancy. Lung clearance index (LCI) is the most reported VI outcome. This study aimed to evaluate historically published reference equations for sulphur hexafluoride (SF6) MBW outcomes, to data collected using updated commercial SF6MBW equipment and to produce device specific equations if necessary.
Method SF6MBW was performed in 327 healthy children aged 0.1-18.4 years (151 [46%] girls), 191 (58.4%) < 3 years. Z-scores were calculated from published reference equations (FRC and LCI) and multivariate linear regression performed to produce device specific reference equations. Due to increasing residual standard deviations with increasing LCI values, investigation of methods for improvement, were investigated, based on the relationship between VI and dead space ventilation (VD/VT; dead space volume/tidal volume) in a cohort of 59 healthy children, 26 children with CF (n=138 test occasions) and 49 adults with lung disease.
Results Historical SF6MBW reference equations were unsuitable for Exhalyzer D® data. In contrast to LCI and log10(LCI), 1/LCI (ventilation distribution efficiency; VDE) was linearly related to VD/VT, with z-scores linearly related to its absolute values. Reference equations were reported for VDE and log10(FRC). Significant predictors for VDE and log10(FRC), respectively, were log10(age) and gender, and log10(height), gender and posture.
Conclusion 1/LCI (e.i., FRC/CEV[%]) reflecting ventilation distribution efficiency (VDE) in the lungs was a superior index of ventilation inhomogeneity compared to LCI and log10(LCI) due to its linear relationship to VD/VT.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was supported by a Vertex Innovation Award; the Research Fund at Skaraborg Hospital, Skovde, Sweden; the SAKS Research Foundation, Uppsala, Sweden; the Children's Lung Foundation (Denmark); and the research foundation at Copenhagen University Hospital, Rigshospitalet, Denmark.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics Committee approval was obtained from the University of Gothenburg, Sweden (DNR 746-15) for the Swedish data collection and from the Ethics Committee of Capital Region of Denmark (H-18057001) for the Danish data collection. All parents provided written informed consent prior to participation in the study.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
↵* shared last authors
New and noteworthy: Lung clearance index (LCI) is the most used outcome from the multiple breath washout test. As known for decades the LCI is not linearly related to dead space ventilation, giving difficulties interpreting changes over time and in clinical trials. We present a new and improved outcome based on LCI - the ventilation distribution efficiency (VDE) which solve this problem by being linearly related to dead space ventilation. A reference equation for VDE is presented.
Funding: This study was supported by a Vertex Innovation Award; the Research Fund at Skaraborg Hospital, Skövde, Sweden; the SAKS Research Foundation, Uppsala, Sweden; the Children’s Lung Foundation (Denmark), and the research foundation at Copenhagen University Hospital, Rigshospitalet, Denmark.
Data Availability
All data produced in the present study are available upon reasonable request to the authors