Abstract
Introduction The common approach for organ segmentation in hybrid imaging relies on co-registered CT (CTAC) images. This method, however, presents several limitations in real clinical workflows where mismatch between PET and CT images are very common. Moreover, low-dose CTAC images have poor quality, thus challenging the segmentation task. Recent advances in CT-less PET imaging further highlight the necessity for an effective PET organ segmentation pipeline that does not rely on CT images. Therefore, the goal of this study was to develop a CT-less multi-tracer PET segmentation framework.
Methods We collected 2062 PET/CT images from multiple scanners. The patients were injected with either 18F-FDG (1487) or 68Ga-PSMA (575). PET/CT images with any kind of mismatch between PET and CT images were detected through visual assessment and excluded from our study. Multiple organs were delineated on CT components using previously trained in-house developed nnU-Net models. The segmentation masks were resampled to co-registered PET images and used to train four different deep-learning models using different images as input, including non-corrected PET (PET-NC) and attenuation and scatter-corrected PET (PET-ASC) for 18F-FDG (tasks #1 and #2, respectively using 22 organs) and PET-NC and PET-ASC for 68Ga tracers (tasks #3 and #4, respectively, using 15 organs). The models’ performance was evaluated in terms of Dice coefficient, Jaccard index, and segment volume difference.
Results The average Dice coefficient over all organs was 0.81±0.15, 0.82±0.14, 0.77±0.17, and 0.79±0.16 for tasks #1, #2, #3, and #4, respectively. PET-ASC models outperformed PET-NC models (P-value < 0.05). The highest Dice values were achieved for the brain (0.93 to 0.96 in all four tasks), whereas the lowest values were achieved for small organs, such as the adrenal glands. The trained models showed robust performance on dynamic noisy images as well.
Conclusion Deep learning models allow high performance multi-organ segmentation for two popular PET tracers without the use of CT information. These models may tackle the limitations of using CT segmentation in PET/CT image quantification, kinetic modeling, radiomics analysis, dosimetry, or any other tasks that require organ segmentation masks.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by the Euratom research and training programme 2019-2020 Sinfonia project under grant agreement No 945196.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study was approved by the Ethics committee of the Canton of Geneva, Switzerland. Consent forms were waived owing to the retrospective nature of the study.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
Datasets are not publicly available. The nnU-Net trained models will be available on Github oage of the first author.
Abbreviations
- PET
- Positron Emission Tomography
- CT
- Computed Tomography
- NC
- Non-Corrected
- ASC
- Attenuation and Scatter Corrected
- PSMA
- Prostate Specific Membrane
- Antigen FDG
- Fluorodeoxyglucose
- NET
- Neuroendocrine tumor
- UB
- Urinary Bladder
- AG
- Adrenal Glands
- CTDIvol
- Volumetric Computed Tomography Dose Index