Abstract
Even though Magnetic Resonance Imaging (MRI) exams are performed up to 16 times per every 100 inhabitants each year, patient comfort and acceptance rates are strongly compromised by exposure to loud acoustic noise. Here we present a system for acoustic noise cancellation using anti-noise derived from predicted scanner sounds. In this approach, termed predictive noise canceling (PNC), the acoustic fingerprint of an MRI system is obtained during a 60 s calibration, and used to predict anti-noise for arbitrary scan procedures. PNC achieves acoustic noise attenuation of up to 13 dB across a wide range of clinical MRI sequences, with spectral noise peak reduction of up to 96.76 % occurring between 0.6 and 1.2 kHz. These results suggest that predicted scanner noise can achieve substantial in-bore noise cancellation with the prospect of providing a cheap and scanner-independent solution for improved patient comfort.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This project was co-funded by the Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) Start-up Grant, STU.019.024; the 4TU Precision Medicine program supported by High Tech for a Sustainable Future; and the European Union ERC StG, VascularID, 101078711.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Footnotes
This project was co-funded by the Nederlandse Organisatie voor Weten-schappelijk Onderzoek (NWO) Start-up Grant, STU.019.024; the 4TU Precision Medicine program supported by High Tech for a Sustainable Future; and the European Union ERC StG, VascularID, 101078711.
Data Availability
All experimental acoustic noise data, animated abstract and other supplementary videos can be found at https://gitlab.tudelft.nl/mars-lab/predictive-noise-canceling.
https://gitlab.tudelft.nl/mars-lab/predictive-noise-canceling