ABSTRACT
The present study compares the ability of distinct immunological assays (chemiluminescence immunoassay-CLIA, western blot-WB and flow cytometry-FC-Simplex and Duplex) to detect anti-HTLV antibodies in candidates for blood donations at the Amazonas State Blood Center (Brazil) between January 2018 and December 2022. Overall, 257,942 samples from candidates for blood donations were screened using CLIA, which led to 0.15% seropositivity for HTLV (409 samples). A total of 151 candidates for blood donations were enrolled for retesting with CLIA followed by additional testing using WB and FC-Simplex and Duplex analysis. Our results demonstrated that 62% (93/151), 20% (30/151) and 17% (26/151) of the samples presented positive results with retesting using CLIA, WB and FC-Simplex analysis, respectively. Additional analysis of the CLIA, WB and FC-Simplex results revealed an overall agreement of 56% for CLIA and WB (22 co-negative; 30 co-positive samples), 48% for CLIA and FC-Simplex (21 co-negative; 24 co-positive samples) and 80% for WB and FC-Simplex (51 co-negative; 23 co-positive samples). Considering the WB as the reference standard for the diagnosis of infection with HTLV-1/2, we observed that the CLIA results of ≤3.0 RLU and >10.0 RLU in the retest can be used define a negative or positive result, respectively, and could be used as new specific cut-off values. The overall agreement between WB and FC-Duplex for accomplishing the differential diagnosis was evaluated and demonstrated 100% correspondence for the diagnosis of HTLV-1 (15/15) and HTLV-2 (7/7). Our findings demonstrate that gaps in the diagnosis of infection with HTLV-1/2 could be overcome by the simultaneous use of distinct immunological assays during retesting of candidates for blood donations.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Yes
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The present study was submitted to and approved by the Ethical Committee at Fundação HEMOAM, under the protocol registration number #739.563/2014. The participants read and signed the informed consent form prior to inclusion in the study. The study fulfills the principles of the Declaration of Helsinki and resolution 466/2012 of the Brazilian National Health Council for research involving human participants.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
Due to ethical restrictions regarding patient privacy, data are available upon request. Data are available upon request from the Ethics Committee of Fundação Hospitalar de Hematologia e Hemoterapia do Amazonas (CEP-HEMOAM - cephemoam{at}gmail.com), for researchers who meet the criteria for access to confidential data. Additional requests for the data may be sent to the corresponding author or coauthors Allyson G. Costa (allyson.gui.costa{at}gmail.com) and Olindo A. Martins-Filho (oamfilho{at}gmail.com).