Abstract
Background The fibrosis-4 (FIB-4) index has attracted attention as a predictive factor for cardiovascular events and mortality in patients with heart disease. However, its clinical value in patients with implanted pacemakers remains unclear.
Methods This study included patients who underwent pacemaker implantation. The FIB-4 index was calculated based on blood tests performed during the procedure. The primary outcome was all-cause mortality, and secondary outcomes included cardiovascular and non-cardiovascular death. The FIB-4 index was stratified into tertiles. Between-group comparisons were performed using log-rank tests and multivariate analysis using Cox proportional hazards. The predictive accuracy and cut-off value of the FIB-4 index were calculated from the receiver operating characteristic curve for all-cause mortality.
Results This study included 201 participants, of whom 38 (incidence rate: 5.8/100 person-years) experienced death events during the observation period (median: 1097 days). All-cause and non-cardiovascular death differed significantly between groups stratified by the FIB-4 index tertiles (log-rank test: P<0.001 and P<0.001, respectively). Using Cox proportional hazards analysis, the unadjusted hazard ratio was 4.75 (95% confidence interval [CI]: 2.05–11.0, P<0.001) for Tertile 3 compared to Tertile 1. After adjustment for confounding factors, including age, sex, the presence or absence of left bundle branch block at baseline, QRS duration during pacing, and pacing rate at the last check, the hazard ratio was 3.61 (95% CI: 1.37–9.48, P=0.009). The cut-off of the FIB-4 index was 3.75 (area under the curve: 0.72, 95% CI: 0.62–0.82).
Conclusions The FIB-4 index was a potential predictive factor for all-cause mortality in patients with implanted pacemakers.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The author(s) received no specific funding for this work.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Not Applicable
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The Ethics Committee on Medical Research of Chutoen General Medical Center (reference no: 1241230822)
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Not Applicable
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Not Applicable
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Not Applicable
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.