Abstract
Background The coronavirus disease 2019 (COVID-19) pandemic has put a strain on the healthcare system, and sudden changes in disease status during home treatment have become a serious issue. Therefore, prediction of disease severity and allocation of sufficient medical resources, including high-flow nasal cannula (HFNC), to patients in need are important. We aimed to determine risk factors for the need of HFNC use in COVID-19.
Methods This was a single-center retrospective observational cohort study including all eligible hospitalized adult patients aged ≥18 years diagnosed with COVID-19 between April 14, 2020 and August 5, 2021 who were treated in the study hospital. The primary outcome was critical respiratory illness meeting one of the following criteria: oxygenation flow rate ≥ 10 L/min, high-flow oxygenation, noninvasive ventilation, invasive ventilation, and death. Nineteen potential predictive variables, including patient characteristics at hospital admission, were screened using least absolute shrinkage and selection operator and logistic regression to construct a predictive risk score. Accuracy of the risk score was determined using area under the receiver operating characteristic curve.
Results The study cohort included 148 patients. The rate of critical respiratory illness was 22.9% (all patients needed high-flow device support). Among the 19 potential variables, percutaneous oxygen saturation (SpO2) <92% (odds ratio [OR] 7.50, 95% confidence interval [CI] 2.806–20.82) and IL-6 (OR 1.021, 95% CI 1.010–1.033) were included in developing the risk score, which was termed interleukin (IL)-6-based COVID-19 severity (IBC-S) score.
Conclusions The IBC-S score, an easy-to-use risk score based on parameters available at the time of hospital admission, predicted critical respiratory failure in patients with COVID-19. In primary care settings, the IBC-S score based on interleukin-6 and SpO2 might aid in determining patients who should be transported to a tertiary medical institution or an isolation facility.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The authors received no specific funding for this work.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The current study was approved by the Institutional Clinical Review Board of Saitama Medical Center, Jichi Medical University (approval no: Clinical # S21-024). In accordance with the ethical guidelines for medical and health research involving human subjects in Japan, written informed consent was not required due to the retrospective study design. The study was conducted with the online opt-out method accessed through the hospital website.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All relevant data are within the manuscript and its Supporting Information files.
List of abbreviations
- COVID-19
- coronavirus disease 2019
- HFNC
- high-flow nasal cannula
- SpO2
- percutaneous oxygen saturation