Abstract
Background Magnetic resonance arterial spin labeling (ASL) imaging with multiple post-labeling delays (PLDs) provides the bolus arrival time (BAT) as well as cerebral blood flow (CBF) to characterize the cerebral hemodynamics. However, the complexity of data acquisition and processing inhibits the calculation of BAT. We developed a simple method for approximating BAT using single-PLD ASL imaging and single-photon emission computed tomography (SPECT). We conducted a proof-of-concept study in patients with carotid artery stenosis.
Methods We introduced the ASL/SPECT ratio, calculated by dividing the tissue magnetization in pulsed continuous ASL by the CBF measured using SPECT. In theory, the ASL/SPECT ratio has a positive relationship with BAT. Our proof-of-concept study included 63 patients who underwent carotid endarterectomy (CEA) in our hospital from 2014 to 2019. After preprocessing the ASL and SPECT datasets using three-dimensional stereotactic surface projection, we calculated the ASL/SPECT ratio at each voxel. We investigated the correlation between the preoperative BAT and the postoperative CBF.
Results We found a positive correlation between the delay of BAT and the increase rate of CBF in the ipsilateral middle cerebral artery territory (Pearson’s correlation coefficient, 0.444; 95% confidence interval, 0.220–0.623; p=0.000269). Four patients (6.3%) presented with hyper-perfusion phenomenon. Visualization of the BAT revealed that the area prone to postoperative hyper-perfusion presented with a delayed preoperative BAT.
Conclusions Our findings suggest the feasibility of the BAT approximated using ASL and SPECT in patients with chronic steno-occlusive cerebrovascular diseases. The proposed concept is also applicable to ASL and any modalities that measure CBF.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
None
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This retrospective study was approved by the Institutional Ethics Review Board of Kohnan Hospital (2021-0520-4).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Non-standard Abbreviations and Acronyms
- ASL
- arterial spin labeling
- BAT
- bolus arrival time
- CBF
- cerebral blood flow
- CEA
- carotid endarterectomy
- ICA
- internal carotid artery
- MCA
- middle cerebral artery
- MR
- magnetic resonance
- pCASL
- pulsed continuous ASL
- PLD
- post-labeling delay
- ROI
- region of interest
- SPECT
- single-photon emission computed tomography
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, The University of Edinburgh, University of Washington, and Vrije Universiteit Amsterdam.