Abstract
Irregular time-series (ITS) are prevalent in the electronic health records (EHR) as the data is recorded in EHR system as per the clinical guidelines/requirements but not for research and also depends on the patient health status. ITS present challenges in training of machine learning algorithms, which are mostly built on assumption of coherent fixed dimensional feature space. In this paper, we propose a computationally efficient variant of the transformer based on the idea of cross-attention, called Perceiver, for time-series in healthcare. We further develop continuous patient state attention models, using the Perceiver and the transformer to deal with ITS in EHR. The continuous patient state models utilise neural ordinary differential equations to learn the patient health dynamics, i.e., patient health trajectory from the observed irregular time-steps, which enables them to sample any number of time-steps at any time. The performance of the proposed models is evaluated on in-hospital-mortality prediction task on Physionet-2012 challenge and MIMIC-III datasets. The Perceiver model significantly outperforms the baselines and reduces the computational complexity, as compared with the transformer model, without significant loss of performance. The carefully designed experiments to study irregularity in healthcare also show that the continuous patient state models outperform the baselines. The code is publicly released and verified at https://codeocean.com/capsule/4587224.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported in part by the National Institute for Health Research (NIHR) Oxford Biomedical Research Centre (BRC) and in part by InnoHK Project Programme 3.2: Human Intelligence and AI Integration (HIAI) for the Prediction and Intervention of CVDs: Warning System at Hong Kong Centre for Cerebro-cardiovascular Health Engineering (COCHE). V. K. Chauhan is supported by a Medical Research Council (MRC) Research Grant (MR/W01761X/1).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
This work was supported in part by the National Institute for Health Research (NIHR) Oxford Biomedical Research Centre (BRC) and in part by InnoHK Project Programme 3.2: Human Intelligence and AI Integration (HIAI) for the Prediction and Intervention of CVDs: Warning System at Hong Kong Centre for Cerebro-cardiovascular Health Engineering (COCHE). V. K. Chauhan is supported by a Medical Research Council (MRC) Research Grant (MR/W01761X/1).
The views expressed are those of the authors and not necessarily those of the NHS, the NIHR, the Department of Health, the InnoHK – ITC or the MRC.
(e-mail: {vinod.kumareng.ox.ac.uk, anshul.thakureng.ox.ac.uk, odhran.odonoghueeng.ox.ac.uk, omid.rohanianeng.ox.ac.uk}, davidc{at}robots.ox.ac.uk)
A preliminary version of this work has been reported [1].
Data Availability
All data produced are available online at https://physionet.org/content/challenge-2012/1.0.0 and https://mimic.mit.edu/