Abstract
The ARTIC protocol uses a multiplexed PCR approach with two primer pools tiling the entire SARS-CoV-2 genome. Primer pool updates are necessary for accurate amplicon sequencing of evolving SARS-CoV-2 variants with novel mutations. The suitability of the ARTIC V4 and updated V4.1 primer scheme was assessed using whole genome sequencing of Omicron from clinical samples using Oxford Nanopore Technology. Analysis of Omicron BA.1 genomes revealed that 93.22% of clinical samples generated improved genome coverage at 50x read depth with V4.1 primers when compared to V4 primers. Additionally, the V4.1 primers improved coverage of BA.1 across amplicons 76 and 88, which resulted in the detection of the variant defining mutations G22898A, A26530G and C26577G. The Omicron BA.2 sub-variant (VUI-22JAN-01) replaced BA.1 as the dominant variant by March 2022, and analysis of 168 clinical samples showed reduced coverage across amplicons 15 and 75. Upon further interrogation of primer binding sites, a mutation at C4321T (present in 163/168, 97% of samples) was identified as a possible cause of complete dropout of amplicon 15. Furthermore, two mutations were identified within the primer binding regions for amplicon 75: A22786C (present in 90% of samples) and C22792T (present in 12.5% of samples). Together, these mutations may result in reduced coverage of amplicon 75 and further primer updates would allow the identification of the two BA.2 defining mutations present in amplicon 75; A22688G and T22679C. This work highlights the need for ongoing surveillance of primer matches as circulating variants evolve and change.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was performed as a diagnostic lab validation as part of the sequencing service established by the Scottish Government.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This work was performed as a diagnostic lab validation and ethical approval was obtained from the NHS Lothian NRS BioResource and Tissue Governance Unit (reference 10/S1402/33).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The data have been deposited with links to BioProject accession number PRJNA902683 in the NCBI BioProject database (http://www.ncbi.nlm.nih.gov/bioproject/902683).
Data Availability
The data have been deposited with links to BioProject accession number PRJNA902683 in the NCBI BioProject database (http://www.ncbi.nlm.nih.gov/bioproject/902683).