Abstract
Objective How responsive neurostimulation (RNS) decreases seizure frequency is unclear. Stimulation may alter epileptic networks during inter-ictal epochs. Since fast ripples (FR) may be a substrate of the epileptic network, we examined whether stimulation of FR generating networks differed in RNS super- and intermediate-responders.
Methods In 10 patients, we detected FR during sleep from stereo EEG (SEEG) contacts during the pre-surgical evaluation in patients with subsequent RNS placement. The normalized coordinates of the SEEG contacts were compared with that of the eight RNS contacts, and RNS stimulated SEEG contacts were defined as within 1.5 cm3 of the RNS contacts. We compared the post-RNS placement seizure outcome to 1) the ratio of stimulated SEEG contacts in the seizure-onset zone (SOZ SR); 2) the ratio of FR events on stimulated contacts (FR SR); and 3) the global efficiency of the FR temporal correlational network on stimulated contacts (FR SGe).
Results We found that the SOZ SR (p=0.18) and FR SR (p=0.06) did not differ in the RNS super- and intermediate-responders, but the FR SGe did (p=0.02). In super-responders highly active desynchronous sites of the FR network were stimulated.
Significance RNS that better targets FR networks, as compared to the SOZ, may reduce epileptogenicity more.
Short summary Responsive neurostimulation (RNS) may reduce seizures by altering the epileptic network. Fast ripples (FR) may be a substrate of the epileptic network. We investigated, in 10 patients, if RNS stimulation of FR generating brain differed in RNS super-responders and intermediate-responders. The RNS stimulated brain sites were defined as contacts in the pre-surgical stereo EEG implant within 1.5 cm3 of the subsequently placed RNS stimulation contacts. FR events were more highly active and temporally desynchronous (p<0.05) on the stimulated contacts in the RNS super-responders. We show RNS that better targets FR networks, as compared to the seizure onset zone, may reduce epileptogenicity more.
Introduction
The responsive neurostimulator system (RNS) is increasingly utilized by clinicians to reduce seizure frequency in patients with seizure onset zone(s) located bilaterally or in eloquent cortex1–3. The RNS is a closed-loop neurostimulator that responds to specific intracranial EEG (iEEG) activity. An implanted intracranial programmable neurostimulator is connected to two four contact depth electrode and/or subdural electrode leads. These leads are placed in the region of a presumed seizure onset zone(s). The neurostimulator continually measures the iEEG activity via the recording contacts and delivers electrical stimulation in response to detection of activity that differ from the usual background. The physician can easily calibrate the threshold for the detection of deviation of EEG signals and the stimulation parameters.
Placement of the RNS device was initially thought to reduce seizure frequency by stimulating during ictal epochs and aborting the seizure4. However, the RNS device stimulates the brain over 1000 times a day and almost entirely during the inter-ictal epoch5. Seizure frequency decreases gradually over years following RNS3. Also, RNS efficacy is better predicted by the features of stimulation during inter-ictal rather than ictal epochs6. Furthermore, closed- and open-loop stimulation have been shown to be similarly effective7. One study found that a reduction in seizure frequency, following RNS placement, is correlated with measures of coherence in the low frequency iEEG, measured over 1-3 years post implant8. Thus, the efficacy of RNS may be more strongly related to induced alterations in the epileptic network8.
We hypothesize that the RNS mechanism of action is to modulate fast ripple (FR) networks and reduce seizures because of the intrinsic role of FR in epileptogenicity and ictogenesis9–13. Alternatively, FR may be just a biomarker of the epileptogenic zone (EZ) that is well suited for targeting by RNS11. We have previously found that patients with seizure improvement after RNS placement have a less widespread FR network with less highly active desynchronized FR sites as compared to: 1) patients not offered an RNS because of widespread seizure onset zones; and 2) non-responders to resection. These results implicate modulation of FR networks in seizure reduction following RNS placement11.
Methods
The institutional review board (IRB) at Thomas Jefferson University (TJU) and University of California, Los Angeles (UCLA) approved the acquisition and secondary analysis of the data used in this study. Data were collected for research purposes without impacting diagnostic studies or clinical decision-making.
This retrospective neurophysiological study used clinical iEEG recordings from 6 patients who underwent intracranial monitoring with stereo EEG (SEEG) electrodes between at UCLA and 4 patients at TJU between 2015 and 2018 for the purpose of localization of the seizure onset zone. Patients had pre-implant T1-weighted magnetic resonance imaging (MRI) for MRI-guided stereotactic electrode implantation, a post-implant CT scan to localize the depth electrodes, and a post-RNS placement CT scan to localize RNS stimulation contacts. Clinical iEEG (2000 samples per second; 0.1–600 Hz) was recorded from the SEEG contacts during sleep (Supplemental Methods). The recordings from the RNS leads were not analyzed in this study. The attending neurologist determined the seizure onset zone (SOZ) from review of video-EEG of the patient’s habitual seizures. For each patient electrodes contacts labeled as the SOZ were aggregated across all seizures and did not include areas of early propagation. Post-RNS implant outcome using the classification scheme of Khambhati in which super-responders are defined as greater than 90% reduction in seizures, and intermediate responders as a 50-90% reduction in seizures8. Outcome was determined using the patient reported clinical seizures at the time of most recent clinic visits compared to baseline reported clinical seizure frequency prior to RNS implantation.
Individual, electrode contacts were labeled in the post-implant and post-RNS CT and coregistered with the pre-implant MRI and then projected in to normalized MNI coordinates (Supplemental Methods). SEEG contacts stimulated by the RNS were determined as SEEG contacts within a radius of 1.5 cm from any one of the eight RNS stimulation contacts (Supplemental Methods).
High-frequency oscillations (HFOs) and sharp-spikes were detected and characterized using previously published methods implemented in Matlab (Mathworks, Natick, MA, USA)(Supplemental Methods). We selected only fast ripple on oscillations with a spectral content > 350 Hz and all fast ripple on spikes for our analysis because they have a higher propensity to be generated in epileptogenic regions11,13. The SOZ stimulation ratio (SOZ SR) was defined as the total number of RNS stimulated SOZ SEEG contacts in the numerator and the total number of SOZ SEEG contacts in the denominator. The FR stimulation ratio (FR SR) was defined as the total number of FR events on RNS stimulated contacts in the numerator and the total number of FR events recorded by all the SEEG contacts in the denominator. The FR stimulated global efficiency (FR SGe) was derived by calculating an adjacency matrix of the mutual information (MI) between FR spike trains, defined by the FR onset time, between stimulated and first-degree neighboring contact pairs and then using Brain Connectivity Toolbox function charpath.m (Supplemental methods).
The Mann-Whitney U test was used to compare the SOZ SR, FR SR, and RR SGe between the RNS super-responders group and the intermediate-responders group. We did not correct for multiple comparisons because we used only three planned comparisons and had a small sample size. Brainnet viewer was used for visualization (Supplementary Methods).
Results
Three of the ten patients who were treated with RNS placement were classified as super responders (S), and the other seven as intermediate responders (I)8. No patients were classified as poor responders. The RNS was placed at least four years prior to outcome determination (Table 1). In all the patients all eight contacts were used for stimulation. We found no obvious relationship between the lead type or the time from RNS implantation to last follow up with RNS outcome in our small cohort (Table 1).
We determined the pre-RNS placement SEEG contacts that could be considered as stimulated by the RNS system after the device had been placed. In our cohort, the RNS stimulation parameters had changed many times since implantation. Since stimulation parameters have been found not to strongly predictive of outcome14, we did not incorporate the individual most recent stimulation parameters into our calculations for identifying the stimulated contacts. Instead, we defined the pre-implant SEEG electrode stimulated contacts as within a radius of <1.5 cm (Supplemental Methods) of the eight RNS contacts (i.e., two leads of either a four-contact depth or subdural strip). Our justification for using this method, and a threshold distance of <1.5 cm, was that RNS stimulation intensities typically ranged from ∽1-3 mAmps at UCLA and TJU, and if the stimulation was monopolar, the stimulation would produce an electric field of ∽2-4 mV/mm at 1.5 cm away from the stimulation source15. Electric field strengths of at least 2-4 mV/mm can induce spike field coherence16,17, and smaller fields at distances greater than 1.5 cm may only influence spike timing18. Notably, a closer proximity of stimulation contacts to epileptogenic regions was required for typical RNS stimulation parameters to abort seizures4, but we were interested in inter-ictal effects. Our model ignores the exact placement of the contacts in gray or white matter, the stimulation train frequency and duration, and the number of stimuli delivered each day and therefore introduces considerable variability, and many confounds. However, we were most interested in comparing the relative proximity of RNS stimulation contacts to FR networks as compared to the SOZ.
After designating the SEEG contacts stimulated by RNS, we compared whether the proportion of stimulated SOZ contacts (SOZ stimulation ratio [SR]), and proportion of FR generated on the stimulated contacts (FR SR) differed for the RNS super-responder patients. Next, by comparing the FR event timing across the stimulated contacts and their first-degree neighbors, we asked if the FR temporal synchrony that defines the FR network would differ in the super-responders. In a prior study, we had found that temporally desynchronous nodes of the FR network also generate FR at higher rates and, if left unresected, correlate with a non-seizure free outcome13. Therefore, we hypothesized that in the super responders the stimulated FR networks would be more desynchronous. To measure the synchrony of the stimulated FR network we used the FR stimulated global efficiency (FR SGe).
We found that the 3 super-responders exhibited no difference in the SOZ SR compared to the intermediate-responders (p=0.18, Figure 1A1,B). The FR SR measured using FR detected during sleep in the SEEG implant trended higher in the super-responders (p=0.06, Figure 1A2,1C) indicating a less widespread FR network that is better targeted by RNS stimulation. In the super-responders the FR SGe was significantly lower (p=0.02, Figure 1A3,1D) indicating that in the three super responders the RNS leads were targeting more desynchronized sites in the FR network13, as compared to the intermediate-responders. In summary, results show that the three super-responders exhibited significantly more proximity of the RNS stimulation contacts to desynchronous, and highly active13, sites in the FR network in comparison to the full extent of the SOZ.
Discussion
RNS may derive its efficacy in reducing seizure burden by inducing neuroplastic changes in epileptic networks over months and years3,6–8. Epileptic networks are theoretical concepts and can be derived in a multitude of ways such as coherence changes in lower-frequency EEG rhythms measured by the patient’s RNS system8. Fast ripples are known to be important in epileptogenesis, the generation of epileptiform discharges, and seizure genesis and could potentially be one of the more important substrates of the epileptic network11–13. Our results show that RNS super-responders had the most active and desynchronous sites of their FR network targeted by the RNS stimulation electrodes. However, since this study did not establish causality, FR networks may merely be the biomarkers of the EZ11, which when targeted by RNS improves seizure frequency reduction irrespective of modulation of FR generation.
FR are thought to be generated by microcircuits known as pathologically interconnected neurons (PIN) clusters9. It is conceptualized that in epileptic networks these PIN clusters act as internal kindling generators that recruit additional territories over months and years and promote seizures on a shorter time scale9. The individual FR events are known to propagate from one region to another10,12 and have been associated with the generation of epileptiform spikes12. Potentially, stimulation by the RNS system could reduce the probability of activation of these PIN clusters and reduce seizure probability9. Further work investigating the effects of closed- and open-loop neurostimulation in the experimental epilepsies is required to further examine this hypothesis.
Our study had several important limitations. As noted in the results, our methodology for deriving the stimulated electrodes was greatly simplified. Electrical fields from a monopolar source decrease proportional to the inverse square of the distance, and furthermore whether these fields induce spike-field coherence or not is not an absolute. Therefore, at the very least, our results imply only that FR generating sites and networks are more proximal to RNS stimulation contacts in super-responders, as compared with the SOZ contacts. Additionally, our study cohort was very small, and these results need to be repeated in a larger cohort. Based on our sample size, a much larger cohort is required to prove statistical superiority of the FR SR or FR SGe as compared to the SOZ SR. Future works should also utilize statistical models that account for other factors, such as the location of the SOZ and the baseline seizure frequency, that can also potentially influence RNS seizure outcome. Finally, all the epileptogenic regions may not have been spatially sampled by the SEEG implant which would impact interpretation of all three SEEG derived measures.
In conclusion, our small study shows that, in RNS super-responders as compared to RNS intermediate-responders, the RNS stimulation electrodes are more proximal to highly active desynchronous FR network sites as compared to the SOZ. More work is needed to determine if RNS should target FR networks as opposed to SOZ sites, and if RNS modulates FR networks or rather FR serve solely as a better biomarker of the EZ.
Data Availability
All data produced in the present study are available upon reasonable request to the authors
Funding
This work was fully supported by the National Institute of Health K23 NS094633, a Junior Investigator Award from the American Epilepsy Society (S.A.W.), R01 NS106958 (R.J.S.) and R01 NS033310 (J.E.),
Acknowledgements
The authors thank Mr. Kirk Shattuck, Dr. Iren Orosz, and Mr. Dale Wyeth and Mr. Ted Wyeth for their technical contribution in collecting EEG recordings, and Dr. Iren Orosz and Dr. Richard Gorniak for assistance with the neuroimaging data.