ABSTRACT
Objective Colorectal cancer (CRC) screening disruptions observed during the COVID-19 pandemic put patients at risk for more advanced-stage disease when diagnosed. This budget impact simulation model assessed increased use of multi-target stool DNA [mt-sDNA] or fecal immunochemical [FIT] tests to offset disruption in colonoscopy screening due to COVID-19 in adults at average-risk for CRC, from a United States payer perspective
Main outcomes and measures Compared to the base case (S0; 85% colonoscopy and 15% non-invasive tests), the estimated number of missed CRCs and advanced adenomas (AAs) were determined for four COVID-19-affected screening scenarios: S1, 9 months of CRC screening at 50% capacity, followed by 21 months at 75% capacity; S2, S1 followed by increasing stool-based testing by an average of 10% over 3-years; S3, 18 months of CRC screening at 50% capacity, followed by 12 months of 75% capacity; and S4, S3 followed by increasing stool-based testing by an average of 13% over 3-years.
Results Increasing the proportional use of mt-sDNA improved AA detection by 6.0% (Scenario 2 versus 1) to 8.4% (Scenario 4 versus 3) and decreased the number of missed CRCs by 15.1% to 17.3%, respectively. Increasing FIT utilization improved the detection of AAs by 3.3% (Scenario 2 versus 1) to 4.6% (Scenario 4 versus 3) and decreased the number of missed CRCs by 12.9% to 14.9%, respectively. Across all scenarios, the number of AAs detected was higher for mt-sDNA than for FIT, and the number of missed CRCs was lower for mt-sDNA than for FIT.
Conclusions and relevance Using home-based stool tests for average-risk CRC screening can mitigate the consequences of reduced colonoscopy screening resulting from the COVID-19 pandemic. Use of mt-sDNA led to fewer missed CRCs and more AAs detected, compared to FIT.
Question What is the impact of increasing the use of stool-based screening tests for colorectal cancer (CRC) during the COVID-19 pandemic in the United States?
Findings In this simulation model, increasing the use of stool-based screening tests increased the number of advanced adenomas detected and decreased the number of missed CRC cases. Use of multi-target stool DNA (mt-sDNA) resulted in a higher number of advanced adenomas detected and a lower number of missed CRC cases compared to fecal immunochemical testing (FIT).
Meaning Increased use of mt-sDNA led to fewer missed CRC cases and more advanced adenomas detected, compared to FIT, when simulating reduced colonoscopy screening resulting from the COVID-19 pandemic.
Competing Interest Statement
Lesley-Ann Miller-Wilson, Vahab Vahdat and Durado Brooks are employees and shareholders at Exact Sciences. Paul Limburg serves as Chief Medical Officer for Screening at Exact Sciences
Funding Statement
This work was funded by Exact Sciences.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are simulated outcomes from the Exact Sciences' CRC BIM model.