Abstract
Background Wrist-worn devices can keep track of a person’s daily health status, including those likely to become infected with the SARS-CoV-2 virus. Technological solutions using mobile devices are being developed to predict the time course of COVID-19.
Objective In this proof-of-concept study, we use heart rate data to detect the first sign of infection in people who have been diagnosed with COVID-19 and to monitor the time-course of the illness.
Methods The heart-rate data were analysed using a multiplicative cascade driven by a Gaussian process. This provides two parameters, mean and standard deviation, which when combined with similar parameters estimated from control series, provide a Health Index.
Results For 90% of 31 cases, the Health Index tracked COVID-19 infection with the virus and subsequent recovery. The first-sign of COVID-19 was detected on average nine days before symptoms were reported.
Conclusions Early detection of COVID-19 may lead to a reduction in the spread of the virus. The Heath Index’s potential use for the early detection of complications arising from Long COVID would be an important innovation.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
From Mishra T, Wang M, Metwally AA, Bogu GK, Brooks AW, Bahmani A, et al. Pre-symptomatic detection of COVID-19 from smartwatch data. Nat Biomed Eng. 2020 Dec;4(12):1208-1220. [doi: 10.1038/s41551-020-00640-6] PMID: 33208926 https://storage.googleapis.com/gbsc-gcp-project-ipop_public/COVID-19/COVID-19-Wearables.zip
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced are available online at https://osf.io/mwnx3/
https://storage.googleapis.com/gbsc-gcp-project-ipop_public/COVID-19/COVID-19-Wearables.zip
Abbreviations
- DFA
- detrended fluctuation analysis
- EEG
- electroencephalogram
- GMCM
- gaussian multiplicative cascade model
- HR
- heart rate
- HRV
- heart rate variability
- probability density function
- RHR
- resting heart rate