Abstract
Background and Rationale Approximately 35% of all COVID-19 deaths occurred in Skilled Nursing Facilities (SNFs). In a healthy general population, wearables have shown promise in providing early alerts for actionable interventions during the pandemic. We tested this promise in a cohort of SNFs patients diagnosed with COVID-19 and admitted for post-acute care under quarantine. We tested if 1) deployment of wearables and contact-free biosensors is feasible in the setting of SNFs and 2) they can provide early and actionable insights into deterioration.
Methods This prospective clinical trial has been IRB-approved (NCT04548895). We deployed two commercially available devices detecting continuously every 2-3 minutes heart rate (HR), respiratory rate (RR) and uniquely providing the following biometrics: 1) the wrist-worn bracelet by Biostrap yielded continuous oxygen saturation (O2Sat), 2) the under-mattress ballistocardiography sensor by Emfit tracked in-bed activity, tossing, and sleep disturbances. Patients also underwent routine monitoring by staff every 2-4 h. For death outcomes, cases are reported due to the small sample size. For palliative care versus at-home discharges, we report mean±SD at p<0.05.
Results From 12/2020 - 03/2021, we approached 26 PCR-confirmed SarsCoV2-positive patients at two SNFs: 5 declined, 21 were enrolled into monitoring by both sensors (female=13, male=8; age 77.2±9.1). We recorded outcomes as discharged to home (8, 38%), palliative care (9, 43%) or death (4, 19%). The O2Sat threshold of 91% alerted for intervention. Biostrap captured hypoxic events below 91% nine times as often as the routine intermittent pulse oximetry. In the patient deceased, two weeks prior we observed a wide range of O2Sat values (65-95%) captured by the Biostrap device and not noticeable with the routine vital sign spot checks. In this patient, the Emfit sensor yielded a markedly reduced RR (7/min) in contrast to 18/min from two routine spot checks performed in the same period of observation as well as compared to the seven patients discharged home over a total of 86 days of monitoring (RR 19± 4). Among the patients discharged to palliative care, a total of 76 days were monitored, HR did not differ compared to the patients discharged home (68±8 vs 70±7 bpm). However, we observed a statistically significant reduction of RR at 16±4/min as well as the variances in RR (10±6 vs 19±4/min vs16±13) and activity of palliative care patients vs. patients discharged home.
Conclusion/Discussion We demonstrate that wearables and under-mattress sensors can be integrated successfully into the SNF workflows and are well tolerated by the patients. Moreover, specific early changes of oxygen saturation fluctuations and other biometrics herald deterioration from COVID-19 two weeks in advance and evaded detection without the devices. Wearable devices and under-mattress sensors in SNFs hold significant potential for early disease detection.
Competing Interest Statement
Emfit and Biostrap donated equipment to conduct the study; neither company had any influence on the study design or data interpretation.
Clinical Trial
NCT04548895
Clinical Protocols
https://clinicaltrials.gov/ct2/show/NCT04548895
Funding Statement
This study was funded by Health Stream Analytics, LLC. Emfit and Biostrap donated the biosensor equipment.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This prospective clinical trial entitled "Nursing Homes and COVID-19" has been approved by the Western IRB (Protocol Number: HSA-001), and registered on clinicaltrials.gov as NCT04548895.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The data produced in the present study are available upon reasonable request to the authors and upon the IRB approval.