Abstract
Throughout the SARS-CoV-2 pandemic, multiple waves of variants of concern have swept across populations, leading to a chain of new and yet more contagious lineages dominating COVID-19 cases. Here, we tracked the remarkably rapid shift from Omicron BA.1 to BA.2 sub-variant dominance in the Swedish population during January–March 2022. By analysis of 174,933 clinical nasopharyngeal swab samples using a custom variant-typing RT-PCR assay, we uncover nearly two-fold higher levels of viral RNA in cases with Omicron BA.2. Importantly, increased viral load in the upper pharynx upon BA.2 infection may provide part of the explanation why Omicron BA.2 is more transmissible and currently outcompetes the BA.1 variant across populations.
Introduction
The SARS-CoV-2 pandemic has been characterised by the emergence and subsequent dominance of new variants of concern, such as Alpha B.1.1.7 during late 2020, Delta B.1.617.2 in mid 2021, and the Omicron variant B.1.1.529.1 (BA.1) in late 2021 and early 20221. It is estimated that a peak of nearly 50 million new infections occurred daily world-wide during the Omicron wave of January 2022, far exceeding the peak of 14 million daily Delta infections during April 20212 and signifying an unprecedented level of transmission of Omicron. In late December 2021, during the midst of the Omicron BA.1 wave in Sweden, the Omicron sub-variant BA.2 (B.1.1.529.2) arrived and rapidly spread through the population. At this time, we put in place an RT-PCR assay capable of genotyping Omicron BA.1 cases directly in primary SARS-CoV-2 RT-PCR testing, enabling day-by-day tracking of the BA.1 frequency at massive scale. Here, provide details of this assay and present data from 174,933 clinical nasopharyngeal swab samples analysed with the method in the Swedish population January–March 2022, demonstrating how the Omicron BA.1 wave was outcompeted by BA.2. Importantly, we further report approximately two-fold increased viral quantities detected in Omicron BA.2 cases, suggesting that higher viral load in the upper pharynx may at least partially explain why Omicron BA.2 is more contagious than the BA.1 lineage.
Results and Discussion
We developed a modified version of the CDC SARS-CoV-2 RT-PCR assay3, simultaneously detecting general SARS-CoV-2 infection status (N1-FAM), human RNaseP sample integrity (RP-HEX), and Omicron BA.1-variant status (SBA1-Cy5) leveraging BA.1-specific indels in the spike (S) gene (Fig. 1a). To attain a multiplex assay of high sensitivity and specificity, suitable for RNA-extraction-free RT-PCR on heat-inactivated samples employed in mass testing4, we designed and evaluated 144 combinatorial SBA1-primer-probe sets, matching CDC N1 properties and with minimized amplicon length (Fig. S1a and Supplementary Table 1). We obtained the first in vitro expanded Omicron BA.1 inoculate in Sweden (GISAID Accession ID: EPI_ISL_7452247) which was used as template, identifying Omicron BA.1-specific primer-probe sets (Fig. 1a-b and Fig. S1b). Detection sensitivity and log-linear cycle thresholds (CT) range were similar for the N1 and SBA1 sets in the assay conditions (Fig. 1c). Using 185 clinical nasopharyngeal swab samples of known COVID19-infection status, we validated that addition of SBA1-Cy5 probes did not affect N1 CT values and the sensitivity to detect general SARS-CoV-2 infection in primary RT-PCR (Fig. 1d and Supplementary Table 2). Parallel genotyping of 133 SARS-CoV-2-positive samples using Thermo Fisher TaqMan SARS-CoV-2 Mutation Panel Assay as well as whole-genome sequencing (WGS) provided Omicron-BA.1-case classification that was 100% consistent with our direct RT-PCR assay (Fig1e-f). Omicron (both the BA.1 and BA.2 lineage) carries a C>T substitution in the third base position of the N1 probe, which we confirmed had negligible effect on CT values by tests using CDC N1 and custom Omicron N1 probes (Fig. S1c).
Having optimised and validated the assay, it was deployed to monitor the Omicron BA.1 wave across central Sweden day-by-day, totalling 174,933 nasopharyngeal samples analysed between January 26 – March 8, 2022 (Supplementary Table 3). While BA.1 was the dominant variant among COVID19-positive cases during January, the BA.1 fraction steadily decreased to as low as 11% by March (Fig. 2a). This trend was observed in all monitored healthcare districts across central Sweden (Fig. 2b), indicating that Omicron BA.1 was being outcompeted by another lineage. To trace this variant switch, we whole-genome sequenced and assigned variants to 698 samples picked among SARS-CoV-2-positive cases. Strikingly, 100% of clinical samples typed as Omicron BA.1 negative in our direct RT-PCR assay were found to be of the Omicron BA.2 lineage by WGS (Fig. 2c), lacking the BA.1-specific “EPE” insertion in S gene targeted by our SBA1-probe (Fig. S1a), demonstrating that Omicron BA.2 was the variant outcompeting BA.1 in the Swedish population. Combining these clinically sequenced cases with the validation set of 133 samples mentioned in a previous section, we had classified a total of 801 cases by WGS (Supplementary Table 4), demonstrating >99% agreement with the BA.1 calls obtained directly in the RT-PCR (796/801 samples) (Fig. 2d). Why Omicron BA.2 is more contagious and outcompetes BA.1 is not well understood, indeed the BA.1/BA.2 transition is still ongoing across the world. Our massive RT-PCR dataset allowed us to compare viral levels detected in BA.1 and BA.2 cases. Intriguingly, samples genotyped as BA.1-negative in RT-PCR contained 1.9-fold higher levels of viral RNA than BA.1-positive samples (24.50 vs. 25.43 median N1 CT; P = 1.54×10−180, Mann-Whitney U-test) (Fig. 2e), pointing to a substantial difference in viral load in the pharynx of patients infected with the two different Omicron variants. Importantly, this difference was observable across day-by-day timepoints (Fig. S2c) and was clearly attributable to the Omicron BA.2 variant, as BA.2 completely dominated non-BA.1 cases and viral copy-numbers were similar in Omicron BA.1 and Delta cases sampled in mid-December (P = 0.77, Mann-Whitney U-test) (Fig. 2f). Similar viral loads between Delta and BA.1 has previously been observed5,6 whereas the increased viral load in BA.2 cases was surprising. To ensure that the difference in viral quantity detected in samples of Omicron BA.1 and BA.2 cases was not attributed to our specific RT-PCR assay nor due to difference in amplification of the 3’-end of the SARS-CoV-2 genome (where the N gene is located) due to unequal discontinuous transcription found in coronaviruses7, we subjected 3,392 samples to both our N1/RP/SBA1 assay and an extraction-based assay (SARS-CoV-2 One-Step RT-PCR Kit, RdRp and N Genes, IVD, NZYTech; Supplementary Table 5) targeting N as well as RdRp, located further 5’ inside ORF1ab. Our RT-PCR assay for the N gene showed a strong linear correlation for both N and RdRp in the extraction-based assay (R2 > 0.949) (Fig. S2d) and we indeed confirmed increased copy numbers in BA.1-negative COVID19 samples in both assays and genes probed (Fig. S2e). Furthermore, lineage classification by WGS for 118 of these samples confirmed that BA.1-negative samples were indeed of BA.2 lineage in this analysis (81/81) (Fig. S2f).
Finally, we observed the BA.2-specific ORF3a:H78Y mutation (Supplementary Table 6), found primarily in Denmark8, in around 40% (172/425) of BA.2 cases classified by WGS (Fig. S3a). These cases were found almost exclusively in the southern-most Swedish region in our analysis where it accounted for around 72% of cases (103/144) (Fig. S3b), suggesting a common Danish/Swedish origin. We further found no Delta/Omicron recombination in our WGS data (Fig. S3c) which has been previously reported for few cases in southern Europe9.
Together, we present an effective RT-PCR assay to simultaneously and robustly call general COVID19 status and Omicron BA.1 variant status in a single RT-PCR reaction, which enabled real-time tracking of the Omicron BA.1/BA.2 transition in Sweden at immense scale. We observed that the predominant Omicron BA.1 variant was gradually and consistently outcompeted by Omicron BA.2 throughout Swedish healthcare districts. Importantly, we report that cases of BA.2 infection presented nearly two-fold higher quantities of viral RNA in nasopharyngeal sabs compared to BA.1 infection, suggesting that increased viral load in the upper pharynx may contribute to BA.2 being more contagious than the BA.1 lineage. Our direct Omicron BA.1-typing assay is a directly compatible addition to the well-established CDC N1/RNaseP probe sets and can thus easily be deployed for instant monitoring of the Omicron BA.1/BA.2 transition where needed, avoiding the time-lag and sample-number bottleneck of genotyping by WGS sequencing.
Data Availability
All data produced in the present study are available upon reasonable request to the authors.
Ethics statement
Ethical oversight and approval were obtained by the Swedish Ethical Review Authority (Dnr 2020-01945 and 2022-01139-02, Etikprövningsmyndigheten).
Competing interests
Ola Winqvist is a shareholder of ABC Labs where the clinical diagnostics were performed. Björn Reinius has worked as a consultant on extraction-free SARS-CoV-2 RT-PCR and is shareholder of GeneBeats, which provides such services.
Author contributions
AL performed WGS data processing, performed data analysis and visualisation, prepared figures, and wrote the manuscript. AP performed Thermo Fisher TaqMan SARS-CoV-2 Mutation Panel Assay. OW provided resources and coordinated the project. BR provided resources, coordinated the project, designed the BA.1 assay and performed RT-PCR, analysed the data, prepared figures, and wrote the manuscript. All authors approved the final version of the manuscript.
Funding
This research was supported and funded by the SciLifeLab/KAW national COVID-19 research program project grant (2020.0182, 2020.0241, V-2020-0699), the Swedish Research Council (2017-01723) and the Ragnar Söderberg Foundation (M16/17) to BR.
Sequencing data and code availability
Raw sequencing data has been deposited to ArrayExpress (accession pending) and assembled SARS-CoV-2 genomes have been deposited to GISAID (accession pending). Computational code is available at https://github.com/reiniuslab/OmicronWaves/. All data are available upon request.
Methods
SARS-CoV-2 RT-PCR
The SARS-CoV-2 RT-PCR assay used in this study represents an improved, multiplex-version of our previously described RNA-extraction-free protocol4 with increased sample and reaction volume and increased sensitivity. For each reaction, 24 uL RT-PCR master mix was prepared, containing 7.5 μL TaqPath 1-Step RT-qPCR Master Mix, CG (Thermo Fisher, containing ROX as passive reference), 0.9 μL 10% Tween20 (Sigma), N1 primer-probe mix (IDT 2019-nCov CDC; FAM/BHQ1, Integrated DNA Technologies), SBA1 primer-probe mix (Cy-5/BHQ2; Merck), RNaseP primer-probe mix (HEX/BHQ1; Merck), and nuclease free water up to 24 uL. Primer/Probe concentrations in the final reactions were 246/62 nM (N1), 491/125 nM (SBA1), and 122/37 nM (RNaseP). Primer and probe sequences of the final assay are provided in Supplementary Table 1b. For RT-PCR testing, 6 μL heat-inactivated nasopharyngeal swab sample (in 0.9% saline) was added to optical 96-well PCR plates (EnduraPlate, Applied Biosystems) containing 24 μL master mix, using liquid a handling robot with automatic sample barcode scanner (Fluent 480, Fluent 780, or Fluent 1080; Tecan). Each PCR plate contained an Omicron BA.1 positive control sample and a negative control (water). Plates were sealed and centrifuged for 30 s at 1500 g. RT-PCR was performed on QuantStudio real-time PCR machines (Applied Biosystems) using the QuantStudio Design & Analysis Software v.1.5.2 and temperature cycles: 25 °C for 2 min, 50 °C for 10 min, 95 °C for 2 min, and 40 cycles of 95 °C for 3 s and 56 °C for 30 s. To test log-linear CT range for the N1 and SBA1 primer-probe sets in the assay conditions, a strongly positive Omicron BA.1 clinical sample was serial-diluted 1:10 in steps and RT-PCR was performed in 8 replicates per concentration. To test whether addition of the SBA1 primer-probe affected N1 CTs, we performed SARS-CoV-2 RT-PCR with and without presence of the SBA1 primer-probe set in parallel on 185 clinical samples (133 known positives, 52 negatives) and compared N1 CTs (Fig. 1d). In the parallel genotyping of 133 SARS-CoV-2-positive samples, performed using Thermo Fisher TaqMan SARS-CoV-2 Mutation Panel Assay (according to the manufacturers instructions) and our SARS-CoV-2 N1/RP/SBA1 assay, all Omicron samples were of the BA.1 lineage as demonstrated by WGS. Extraction-based SARS-CoV-2 One-Step RT-PCR Kit, RdRp and N Genes, IVD (NZYTech) was performed according to the manufacturer’s instructions (Version 13/2021, December 2021).
SARS-CoV-2 samples
The in vitro expanded Omicron BA.1 reference sample used for the evaluation of SBA1 primer-probe sets (Fig. S1a-b) was obtained from the Public Health Agency of Sweden (sample isolated Nov 30, 2021; GISAID Accession ID: EPI_ISL_7452247), and the non-Omicron BA.1 reference sample (lacking “S:N211IN212-” and “S:214:EPE”) was an Alpha B.1.1.7 (sample isolated Feb 1, 2021; https://doi.org/10.5281/zenodo.4722502). 174,933 nasopharyngeal swab samples, collected in 0.9% saline solution and analysed January-March 2022 (Supplementary Table 3), were subjected to heat inactivation by 70 °C for 50 min in a hot air oven. These samples were analysed for presences of SARS-CoV-2 as part of clinical diagnostics performed at ABC Labs, Stockholm, by demand of the Public Health Agency of Sweden. The use of the Omicron BA.1 screening protocol was validated at ABC Labs and approved by the Public Health Agency of Sweden. For the purpose and analyses of the current study, sample identities were anonymised, and IDs were replaced by a randomized code (i.e., those listed in supplementary tables). Informed consent for the use of anonymized CT values or samples obtained in routine clinical diagnostics was not obtained and is not required, and is in accordance with the study permit obtained by the Swedish Ethical Review Authority (Dnr 2020-01945 and 2022-01139-02, Etikprövningsmyndigheten).
SARS-CoV-2 WGS
For sequencing of SARS-CoV-2 genomes, we used the Illumina COVIDSeq Test kit and sequencing was performed on the Illumina NextSeq 550 Sequencing System.
Sequencing data analysis
Raw data was quality trimmed using fastp10 v0.20.0 and de novo assembled using MEGAHIT11 v1.2.9 [--min-contig-len 5000]. Disjoint contigs were scaffolded against the SARS-CoV-2 reference genome [ASM985889v3] using RagTag12 v2.1.0 and SARS-CoV-2 lineage was assigned using pangolin13 v3.1.20 [lineages version 2022-02-28]. Alignment statistics was obtained using Minimap214 v2.24-r1122 [-ax sr Sars_cov_2.ASM985889v3.dna_sm.toplevel.fa.gz] and samtools15 v1.10 [stats] [coverage]. Identification of SARS-CoV-2 mutations was performed using Nextclade16v1.14.0. Computational code is available at https://github.com/reiniuslab/OmicronWaves/.
Acknowledgements
We are grateful to members of the Reinius lab and ABC Labs, helping at various stages of the project. In vitro expanded Omicron BA.1 inoculate was kindly provided by the Public Health Agency of Sweden and we thank Sandra Söderholm and Shaman Muradrasoli facilitating transfer of this sample. We thank Jessica Alm at the National Pandemic Centre (NPC), Karolinska Institutet for providing anonymized control samples.