Abstract
Enveloped viruses are prone to inactivation when exposed to strong acidity levels characteristic of atmospheric aerosol. Yet, the acidity of expiratory aerosol particles and its effect on airborne virus persistence has not been examined. Here, we combine pH-dependent inactivation rates of influenza A virus and SARS-CoV-2 with microphysical properties of respiratory fluids using a biophysical aerosol model. We find that particles exhaled into indoor air become mildly acidic (pH ≈ 4), rapidly inactivating influenza A virus within minutes, whereas SARS-CoV-2 requires days. If indoor air is enriched with non-hazardous levels of nitric acid, aerosol pH drops by up to 2 units, decreasing 99%-inactivation times for both viruses in small aerosol particles to below 30 seconds. Conversely, unintentional removal of volatile acids from indoor air by filtration may elevate pH and prolong airborne virus persistence. The overlooked role of aerosol pH has profound implications for virus transmission and mitigation strategies.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was funded by the Swiss National Science Foundation
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Inclusion of NH3 scrubbing as a method to modulate aerosol acidity (Figures 4 and 5 and accompanying text)
Data Availability
All data produced in the present work are either contained in the manuscript or will be made available upon acceptance of the manuscript