Abstract
Background Accurate rapid antibody detection kits requiring minimum infrastructure are beneficial in detecting post-vaccination antibodies in large populations. ChAdOx1-nCOV (COVISHIELD™) and BBV-152 (Covaxin™) vaccines are primarily used in India.
Methods In this single-centre prospective study, performance of Meril ABFind was investigated by comparing with Abbott SARS-CoV-2 IgG II Quant (Abbott Quant), GenScript cPass SARS-CoV-2 neutralization antibody detection kit (GenScript cPass), and COVID Kawach MERILISA (MERILISA) in 62 vaccinated health care workers (HCW) and 40 pre-pandemic samples.
Results In the vaccinated subjects, Meril ABFind kit displayed high sensitivity of 93.3% (CI, 89.83%-96.77%), 94.92% (CI, 91.88%-97.96%), and 90.3% (CI, 86.20%-94.4%) in comparison to Abbott Quant, MERILISA, and GenScript cPass respectively. The results of the Meril ABFind in the COVISHIELD-vaccinated group were excellent with 100% sensitivity in comparison to the other three kits. In the Covaxin-vaccinated group, Meril ABFind displayed sensitivity ranging from 80% to 88.9%. In control samples, there were no false positives detected by Meril ABFind, while Abbott Quant, MERILISA, and GenScript cPass reported 2.5%, 10.0%, and 12.5% false positives, respectively. In the pre-pandemic controls, specificity of Meril ABFind was 100%, Abbott Quant 97.5%, MERILISA 90%, and GenScript cPass 87.5%.
Conclusion The Meril ABFind kit demonstrated satisfactory performance when compared with the three commercially available kits and was the only kit without false positives in the pre-pandemic samples. This makes it a viable option for rapid diagnosis of post vaccination antibodies.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by the Municipal Corporation of Greater Mumbais funding for Kasturba Hospital's COVID-19 diagnostic laboratory. Test kits were provided by Meril Diagnostic Pvt Limited.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The studies involving human participants were reviewed and approved by the Institutional Review Board of Kasturba Hospital of Infectious Diseases; IRB number 05/2021. The patients/participants provided their written informed consent to participate in this study. All collection, processing of samples and archiving of results were performed under approval from Institutional Review Board.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present work are contained in the manuscript