ABSTRACT
On November 26, 2021, the World Health Organisation classified the B.1.1.529 SARS-CoV-2 variant as the Omicron variant of concern (VOC). Reports of higher transmissibility and potential immune evasion triggered flight bans and heightened health control measures across the world to stem its distribution. Wastewater-based surveillance has demonstrated to be a useful complement for community-based tracking of SARS-CoV-2 variants. Using design principles of our previous assays that detect VOCs (Alpha and Delta), here we report three allele-specific RT-qPCR assays that can quantitatively detect and discriminate the Omicron BA.1 and BA.2 variants in wastewater. The first assay targets the nine-nucleotide deletion at the L24-A27S of the spike protein for detection of BA.2. The second targets the six-nucleotide deletion at 69-70 of the spike protein for detection of the Omicron BA.1 variant, and the third targets the stretch of mutations from Q493R to Q498R for simultaneous detection of both Omicron BA.1 and BA.2. This method is open-sourced, can be implemented using commercially available RT-qPCR protocols, and would be an important tool for tracking the introduction and spread of the Omicron variants BA.1 and BA.2 in communities for informed public health responses.
INTRODUCTION
The Coronavirus disease 2019 (COVID-19) was first detected late December 2019 and rapidly spread globally, leading to the WHO declaring it a global pandemic by March 2020 (WHO, 2020). The etiological cause of COVID-19 is the single-stranded RNA virus SARS-CoV-2 of the genus Betacoronavirus, a genus which also contains other human respiratory pathogens such as SARS-CoV and MERS-CoV (Pal et al., 2020). SARS-CoV-2 infection in the respiratory and gastrointestinal tract is mediated by the binding between viral spike protein (S) and human angiotensin-converting enzyme 2 (ACE-2) receptor (Zhou et al., 2020). Over the course of the COVID-19 pandemic, multiple SARS-CoV-2 variants of concern (VOCs) emerged due to genetic mutation of the viral genome. While many variants contain inconsequential mutations, some obtained mutations that confer higher fitness through increased transmissibility and the ability to elude medical countermeasures such as vaccines (Harvey et al., 2021). These variants are deemed by the WHO as variants of concerns due to their increased risk (CDC, 2021). To date, WHO has classified five variants as VOCs. These include Alpha (B.1.1.7), Beta (B.1.351), Gamma (P.1) and the Delta (B.1.617.2), a variant which emerged from India in October 2020 and quickly became the predominant global strain by mid-2021 (WHO, 2021a). Omicron (B.1.1.529), the fifth VOC and its descendent lineages were reported in multiple countries as early as November 2021. The Omicron variant draws attention due to its high number of mutations, with 26-32 of them in the spike protein (WHO, 2021b). The rapid expansion of the Omicron in the South African region and global distribution amidst early reports of higher transmissibility and immune escape compared to the Delta variant raised alarms for researchers and public health officials worldwide (Pulliam et al., 2021).
In light of the emergence of VOCs, surveillance efforts to track their introduction and spread in both naive and vaccinated populations become important to fight the pandemic and contain the spread of SARS-CoV-2. Currently, the most widely-used method for variant surveillance involves sequencing of clinical samples. However, the accessibility of genomic sequencing is limited and unsustainable due to the high capital and operational costs and the associated specialised infrastructure requirements (Gwinn et al., 2019). Furthermore, a significant fraction of confirmed cases needs to be sequenced to generate a meaningful dataset. A complementary method of surveillance that has been drawing a lot of attention during this pandemic is wastewater-based surveillance (WBS). WBS promises a robust, low-cost, real-time, and unbiased (i.e., indiscriminate of the manifestation of symptoms) snapshot of the entire populations within its sewershed/catchment range (Polo et al., 2020; Thompson et al., 2020). WBS has been shown to be effective, specific and comparatively sensitive at determining SARS-CoV-2 circulation trends during this COVID-19 pandemic across different countries (Medema et al., 2020; Randazzo et al., 2020; Wu et al., 2021). Further, WBS has been used to track the introduction and spread of VOC SARS-CoV-2 strains. Most of the efforts for variant tracking in wastewater rely on enriching and sequencing the environmental SARS-CoV-2 genome (Crits-Christoph et al., 2021; Fontenele et al., 2021; Napit et al., 2021). However, poor sensitivity towards low-frequency variants commonly found during the “introduction” of a VOC in a population and the lack of quantitative modelling of the data generated limits widespread application (Van Poelvoorde et al., 2021). RT-qPCR-based methods capable of targeting variant-specific mutants in the SARS-CoV-2 genome have been successfully demonstrated for variant identification in clinical samples (Wang et al., 2021) and we and others have recently adapted and validated use of such assays for quantification of multiple variants in wastewater samples (Graber et al., 2021; Lee et al., 2021a, 2021b, 2021c; Yaniv et al., 2021). RT-qPCR methods enable differentiation of specific variant-linked mutations and are more sensitive than sequence-based approaches, allowing for their quantitation, and providing readily interpretable results within hours and using widely available methods and workflows. However, designing assays for VOCs is a moving target since emerging VOCs may possess unique mutations that necessitate the development of new assays.
Our group has previously designed RT-qPCR-based methods for the detection of mutations associated with the Alpha variant and the Delta variant in wastewater (Lee et al., 2021a, 2021b, 2021c). The assays are designed based on principles of allele-specific (AS-) qPCR (Petruska et al., 1988; Wu et al., 1989). Here, we report three sets of AS RT-qPCR primers for the specific detection of the Omicron BA.1 and BA.2 variants - 1) assay targeting substitutions at loci Q493R to Q498R could be used to detect both Omicron BA.1 and BA.2 variants, 2) assay targeting deletions at loci H69-V70 could be used to detect for Omicron BA.1, 3) assay targeting deletions at loci 24-27 could be used to detect for Omicron BA.2. These assays can be run as a singleplex or as a multiplex (Lee et al., 2021a) for improved convenience.
RESULTS AND DISCUSSION
In this work we report three sets of allele-specific (AS-) RT-qPCR primers that could be used to detect, quantify and differentiate the Omicron variants BA.1 and BA.2 in wastewater, based on mutations present in the spike gene in Omicron (Table 1). The assay targeting loci Q493R to Q498R could be used to detect both Omicron BA.1 and BA.2 variants, the assay targeting loci H69-V70 could be used to detect for Omicron BA.1 and the assay targeting loci 24-27 could be used to detect for Omicron BA.2. These genome sites are selected with reference to CoVariants (GISAID, 2021a). As compared to earlier versions of this work, we have updated the primer and probe sets to also include assays specific for the BA.2 subvariant. Initial validation with RNA templates demonstrate the sensitivity and specificity required for their utilisation in WBS assays.
Specificity and cross-reactivity of AS RT-qPCR primers against Omicron BA.1 or BA.2 and WT RNA
We validated the respective assays against synthetic full length WT and Omicron BA.1 or BA.2 RNA genome constructs (Figure 1). All mutant-specific assays do not cross-react with WT RNA at and below 103 copies, conferring sufficient specificity for determining wastewater titers of the Omicron variants, given that the number of copies of SARS-CoV-2 RNA in each reaction containing RNA template from wastewater has been reported typically below 103 (Duvallet et al., 2021; Wu et al., 2022, 2021, 2020). The amplification efficiencies of all the assays for their target RNA are above 85%.
Using cycle thresholds (Ct) as a proxy for the sensitivity of the assays (Figure 2), we compared Ct values of the AS RT-qPCR assays developed, to those of the U.S. CDC N1 assay across a 10,000-fold difference in target RNA concentrations. WT and BA.1 assays targeting 69-70 and BA.2 assays targeting 24-27 had comparable sensitivities to the N1 assay while the rest of the assays had slightly lower sensitivities compared to the N1 assay. Nonetheless, all assays were able to reproducibly and robustly detect as little as 10 copies of target RNA.
DISCUSSION
The study presented here proposes three AS RT-qPCR assays that have been developed for specific detection and quantitation of the SARS-CoV-2 Omicron variant BA.1 and BA.2 in wastewater samples. The assay targeting loci 69-70 could be used to detect for Omicron BA.1, the assay targeting loci 24-27 for detecting the Omicron BA.2 and the assay targeting loci 493-498 for simultaneous detection of both Omicron BA.1 and BA.2 variants in complex wastewater matrices. All the assays reported in this work are highly specific and did not cross-react with RNA of their respective opposite genotypes in concentrations of up to 103. All assays showed good amplification efficiencies and sufficient sensitivity and specificity to allow for the detection of the Omicron variants in wastewater.
The assay covering locus 69-70 was previously developed for the detection of the SARS-CoV-2 Alpha variant (Lee et al., 2021b,c). Due to co-evolution, the deletion at locus 69-70 can be found in the Alpha and the Eta variants as well as the more recent Omicron BA.1 VOC. While there may be a theoretical ambiguity if a positive read out with this assay would signify the Alpha, Eta or the Omicron BA.1 variant, but as of late Dec 2021, less than 0.2% of newly reported sequences is attributed to the Alpha and the Eta variants (GISAID, 2021b).
While not yet demonstrated in this work, the three assays reported in this work can be combined into a multiplex for greater convenience of handling. Variant detection requires performing only the variant-specific assays, of which the assays targeting the Omicron variant (BA.2 24-27 assay, BA.1 69-70 assay and Omicron 493-498 assay) can be combined into a reaction as a multiplex. Likewise the three WT-specific assays (WT 24-27 assay, WT 69-70 assay and WT 493-498 assay) can be combined as another multiplex. Potential multiplex combinations are shown in Table 4.
While variant detection only requires performing the reaction that targets the mutated locus in the SARS-CoV-2 variant of concern, we present assays that target both the WT and the mutant at the same loci. This way, quantification of both WT and mutant loci in wastewater allows one to determine the proportion of WT to the variant sequence at the target loci, if desired. In the first version of this study, Omicron variant RNA was not yet commercially available in our laboratory. Therefore, the WT assay was utilised to approximate the performance of the Omicron assay. In the subsequent second version, we updated the workflow to include a validation of the 69-70 and 493-498 assays using a full length synthetic Omicron BA.1 RNA construct. Following the emergence of the Omicron BA.2 variant, we further updated this study to include assays targeting loci 24-27 for specific detection of the Omicron BA.2 variant. We are sharing these assays and their initial validations for the benefit of the wider wastewater surveillance community.
MATERIALS AND METHODS
Assay design
We designed AS RT-qPCR reactions to detect a stretch of mutations in the SARS-CoV-2 spike gene. Primers and probes were designed following our previous work (Lee et al., 2021) and using the Integrated DNA Technologies (IDT)’s PrimerQuest Tool. Target mutations were placed near the 3’ end of the forward primer. All primers were designed to have a melting temperature in the range of 59–65°C and the probes in the range of 64–72°C. Probes were designed to anneal to the same strand as the allele-specific primer, with the probe as close to the 3′-end of the Allele Specific (AS) primers as possible. Guanines are avoided at the 5′-end of the probe. WT primers are designed to bind to all non-Omicron sequences. The probe for 493-498 is designed with mixed bases at two positions to enable binding to both WT (non-Omicron) and Omicron sequences. The primer F-WT-24-27 is designed with mixed bases at one position to enable binding to more WT (non-BA.2) sequences. All primers and probes were purchased from IDT (Table 2).
RNA Standards and their quantification by RT-ddPCR
Twist synthetic SARS-CoV-2 RNA control 23 (Delta, B.1.617.2) was used as the WT RNA standard, as it contains the wild-type (WT) sequence at the three targeted mutant loci. Twist synthetic SARS-CoV-2 RNA control 48 (B.1.1.529/BA.1) and 50 (B.1.1.529/BA.2) were used as the RNA standard for Omicron BA.1 and BA.2 respectively. RNA standards were prepared as single-use aliquots. Controls 23, 48 and 50 were quantified by digital droplet RT-PCR (dd RT-PCR) to be 3.96 × 105 copies/μL, 4.55 × 105 copies/μL and 4.21 × 105 copies/μL respectively. Quantification was performed using One-Step RT-ddPCR Advanced Kit for Probes #1864022 (Bio-Rad) following manufacturer’s recommendations.
Analysis of assays against RNA standards by RT-qPCR
AS RT-qPCR was performed using the Taqman Virus 1-Step master mix (Thermofisher #4444434) with technical duplicates, at a final volume of 10 µL, according to the manufacturer’s recommendations. A single reverse primer and probe was used with each allele-specific forward primer (Table 3). The final concentration of the AS RT-qPCR primers were 500 nM, probe at 200 nM, with 1 µL of template. No template controls were included for each assay and none of them amplified. The reactions are setup using electronic pipettes (Eppendorf) and performed on a Bio-Rad CFX384 real-time PCR instrument under the following conditions, 5 min at 50 °C and 20 s at 95 °C, followed by 45 cycles of 3 s at 95 °C and 30 s at 60 °C.
Data analysis
qPCR data was analysed using Microsoft Excel and Graphpad Prism. Graphs were presented using Graphpad Prism.
Data Availability
Source data will be made available upon request.
Declaration of competing interests
EJA is an advisor to Biobot Analytics and holds shares in the company.
Funding Statement
This research is supported by the National Research Foundation, Prime Minister’s Office, Singapore, under its Campus for Research Excellence and Technological Enterprise (CREATE) program funding to the Singapore-MIT Alliance for Research and Technology (SMART) Antimicrobial Resistance Interdisciplinary Research Group (AMR IRG) and the Intra-CREATE Thematic Grant (Cities) grant NRF2019-THE001-0003a to JT and EJA and funding from the Singapore Ministry of Education and National Research Foundation through an RCE award to Singapore Centre for Environmental Life Sciences Engineering (SCELSE).
Contributions
EJA and JT conceptualized the project. WLL designed the experiments. WLL, XG, FA, FC, HC, HC, FW, AX, ML, FJDC and GWCK analyzed the data. WLL, JYRT and CYJL performed experiments. All authors contributed to writing the manuscript. WLL, JT and EJA supervised the project. All authors read and approved the manuscript.
Acknowledgements
We thank members of the Biobot Analytics, Inc team for helpful discussions.
Footnotes
Following the emergence of the Omicron BA.2 variant, we further updated this study to include assays targeting loci 24-27 for specific detection of the Omicron BA.2 variant. We are sharing these assays and their initial validations for the benefit of the wider wastewater surveillance community.