Abstract
The strong humoral immune response produced against the SARS-CoV-2 nucleocapsid (N) and spike (S) proteins has underpinned serological testing but the prevalence of antibody responses to other SARS-CoV-2 proteins, which may be of use as further serological markers, is still unclear. Cell-based serological screening platforms can fulfil a crucial niche in the identification of antibodies which recognise more complex folded epitopes or those incorporating post-translation modifications which may be undetectable by other methods used to investigate the antigenicity of the SARS-CoV-2 proteome. Here, we employed automated high content immunofluorescence microscopy (AHCIM) to assess the viability of such an approach as a method capable of assaying humoral immune responses against full length SARS-CoV-2 proteins in their native cellular state. We first demonstrate that AHCIM provides high sensitivity and specificity in the detection of SARS-CoV-2 N and S IgG. Assessing the prevalence of antibody responses to the SARS-CoV-2 structural membrane protein (M), we further find that 85% of COVID-19 patients within our sample set developed detectable M IgG responses (M sensitivity 85%, N sensitivity 93%, combined N + M sensitivity 95%). The identification of M as a serological marker of high prevalence may be of value in detecting additional COVID-19 cases during the era of mass SARS-CoV-2 vaccinations, where serological screening for SARS CoV-2 infections in vaccinated individuals is dependent on detection of antibodies against N. These findings highlight the advantages of using cell-based systems as serological screening platforms and raise the possibility of using M as a widespread serological marker alongside N and S.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was funded by BBSRC (BB/S009566/1; BB/J014443/1) Wellcome Trust and the Royal Society (216370/Z/19/Z). The Danson Foundation (DAN5819). Sheffield Teaching Hospitals NHS Foundation Trust and Wellcome Trust Intermediate Clinical Fellowship (110058/Z/15/Z).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The ethics committee of the University of Sheffield gave ethical approval for this work.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors.