Abstract
Catheters used for endovascular navigation in interventional procedures lack dexterity at the distal tip. Neurointerventionists, in particular, encounter challenges in up to 25% of aneurysm cases largely due to the inability to steer and navigate the tip of the micro-catheters through tortuous vasculature to access aneurysms. We overcome this problem with sub-millimeter diameter, hydraulically-actuated hyperelastic polymer devices at the distal tip of micro- catheters to enable active steerability. Controlled by hand, the devices offer complete 3D orientation of the tip. Using pressures up to 400 kPa (4 atm) we demonstrate guidewire-free navigation, access, and coil deployment in vivo, offering safety, ease of use, and design flexibility absent in other approaches to endovascular intervention. We demonstrate the ability of our device to navigate through vessels and to deliver embolization coils to the cerebral vessels in a live porcine model. This indicates the potential for microhydraulic soft robotics to solve difficult access and treatment problems in endovascular intervention.
Competing Interest Statement
TG and JF are authors on a patent application US20190209811A1, Hydraulically driven surgical apparatus, submitted by the University of California and which covers design and manufacturing methods for the steerable catheter and control system
Funding Statement
TCG is grateful to the American Heart Association for grant 16PRE31430005, and the American-Australian Association Sir Keith Murdoch Scholarship in support of this project. The authors are grateful for funding provided by the American Heart Association's Innovative Project Award (19IPLOI34760705), the state of California's AB2664 Medical Entrepreneurship Education and Training Grant scheme, UCSD's Galvanizing Engineering in Medicine program, and the National Institutes of Health via the University of California Center for Accelerated Innovation (NIH/ NCATS UCSD CTRI 1UL1TR001442-01).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The animal (porcine) study was approved by the University of California San Diego Animal Care and Use Committee (IACUC) approved protocols S12204 (from 8/17/2016) and S13289 (from 3/15/2017). The use of anonymized DICOM-formatted imagery to produce the vascular in-silicone model was conducted under University of California San Diego's Institutional Review Board's approved protocol 171538, entitled "Prospective and retrospective observational study in human subjects undergoing radiology examinations for clinical care", most recently approved on 28 September 2019.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data needed to evaluate the conclusions in the paper are present in the paper or Supplementary Materials. All data associated with the work will be made available via a UC San Diego Library-maintained link as provided.