Abstract
Background The partial pressure of oxygen (PaO2)/fraction of oxygen delivered (FIO2) ratio is the reference standard for assessment of hypoxemia in mechanically ventilated patients. Non-invasive monitoring with the peripheral saturation of oxygen (SpO2) is increasingly utilized to estimate PaO2 because it does not require invasive sampling. Several equations have been reported to impute PaO2/FIO2 from SpO2 /FIO2. However, machine-learning algorithms to impute the PaO2 from the SpO2 has not been compared to published equations.
Research Question How do machine learning algorithms perform at predicting the PaO2 from SpO2 compared to previously published equations?
Methods Three machine learning algorithms (neural network, regression, and kernel-based methods) were developed using 7 clinical variable features (n=9,900 ICU events) and subsequently 3 features (n=20,198 ICU events) as input into the models from data available in mechanically ventilated patients from the Medical Information Mart for Intensive Care (MIMIC) III database. As a regression task, the machine learning models were used to impute PaO2 values. As a classification task, the models were used to predict patients with moderate-to-severe hypoxemic respiratory failure based on a clinically relevant cut-off of PaO2/FIO2 ≤ 150. The accuracy of the machine learning models was compared to published log-linear and non-linear equations. An online imputation calculator was created.
Results Compared to seven features, three features (SpO2, FiO2 and PEEP) were sufficient to impute PaO2/FIO2 ratio using a large dataset. Any of the tested machine learning models enabled imputation of PaO2/FIO2 from the SpO2/FIO2 with lower error and had greater accuracy in predicting PaO2/FIO2 ≤ 150 compared to published equations. Using three features, the machine learning models showed superior performance in imputing PaO2 across the entire span of SpO2 values, including those ≥ 97%.
Interpretation The improved performance shown for the machine learning algorithms suggests a promising framework for future use in large datasets.
Competing Interest Statement
J.S. Lee discloses a paid consultantship with Janssen Pharmaceuticals, Inc. unrelated to this study. The authors have no other relevant conflicts of interest to disclose.
Funding Statement
This work was supported by the National Heart, Lung, And Blood Institute of the National Institutes of Health under Award Numbers F32 HL152504 (J.Z.); P01 HL114453, R01 HL136143, R01 HL142084, K24 HL143285 (J.S.L.), and R01 LM012011 (X.L. and S.R.). The University of Pittsburgh holds a Physician-Scientist Institutional Award from the Burroughs Wellcome Fund (J.Z.); content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health or any other sponsoring agency.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Our study was determined by the University of Pittsburgh Institutional Review Board to be exempt (STUDY19100068).
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
COI: J.S. Lee discloses a paid consultantship with Janssen Pharmaceuticals, Inc. unrelated to this study. The authors have no other relevant conflicts of interest to disclose.
Abbreviations List
- PaO2
- partial pressure of oxygen
- FIO2
- fraction of oxygen
- PaO2/FIO2
- PF ratio
- SpO2
- peripheral saturation of oxygen
- PEEP
- positive end expiratory pressure
- TV
- tidal volume
- MAP
- mean arterial pressure
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.