Abstract
Drug-induced arrhythmia continues to be a major health issue worldwide. The need for reliable pro-arrhythmic predictors became relevant during early phases of the SarsCoV2 pandemic, when it was uncertain whether the use of hydroxychloroquine (HCQ) and azithromycin (AZM) could be more harmful than beneficial due to their reported pro-arrhythmic effects.
In this work we describe a computational framework that employs a gender-specific, in-silico cardiac population to assess cardiac drug-induced QT-prolongation after the administration of a single or a combination of potentially cardiotoxic drugs as HCQ and AZM. This novel computational methodology is capable of reproducing the complex behavior of the clinical electrocardiographic response to drug-induced arrhythmic risk, in-silico. Using high performance computing, the computational framework allows the estimation of the arrhythmic risk in a population, given a variety of doses of one or more drugs in a timely manner and providing markers that can be directly related to the clinical scenario. The pro-arrhythmic behavior observed in subjects within the in-silico trial, was also compared to supplemental in-vitro experiments on a reanimated swine hearts. Evidence of transmurally heterogeneous action potential prolongation after the administration of a large dose of HCQ was an observed mechanism of arrhythmia, both in the in-vitro and the in-silico model. The virtual clinical trial also provided remarkably similar results to recent published clinical data. In conclusion, the in-silico clinical trial on the cardiac population is capable of reproducing and providing evidence of the normal phenotype variants that produce distinct arrhythmogenic outcomes after the administration of one or various drugs.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This project has received funding from the European Union Horizon 2020 research and innovation programme under grant agreements No 823712 (CompBioMed project, phase 2) and No 777204 (SilicoFCM project). Computation time was provided by PRACE-COVID-19 fast track pandemic response (project COVID1933) at the Joliot-Curie Rome supercomputer, hosted by GENCI at CEA, France. JA-S is funded by a Ramon y Cajal fellowship (RYC-2017-22532), MINECO, Spain. CB is funded by the Torres Quevedo Program (PTQ2018-010290), MINECO, Spain.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The University of Minnesota Institutional Review Board and LifeSource Research Committee
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Human cardiac database is hosted at the Visible Heart Laboratory, University of Minnesota website. Computational model results will become available after peer review publication.