Abstract
Objective To compare the clearness rate of fetal Sylvian fissure revealed by prenatal ultrasonography on trans-cerebellar section and trans-thalamic section, and to provide scientific basis for selecting the best section of prenatal ultrasound to evaluate the developmental parameters related to fetal Sylvian fissure.
Methods This was a retrospective study. We analyzed all the fetal images on trans-cerebellar section and trans-thalamic section stored in the imaging system who were undergoing grade III prenatal ultrasound examination in our hospital from January 2017 to December 2018. The gestational age was divided into three groups which were 21 to 24 weeks, 25 to 28 weeks and 29 to 32 weeks respectively. The evaluation criteria for the clear appearance of the Sylvian fissure were complete morphology of the Sylvian fissure and clear apical and anteriorly edges of the Sylvian fissure. The results of showing Sylvian fissure clearly were divided into four groups: only on trans-cerebellar section shown clear, only on trans-thalamic section shown clear, both on trans-cerebellar section and trans-thalamic section shown clear, and both on trans-cerebellar section and trans-thalamic section not shown clear. The clearness rate of each group and the total clearness rate of each section were analyzed statistically.
Results The clearness rates of showing Sylvian fissure only on trans-cerebellar section were 62.3% at 21 to 24 weeks, 70.1% at 25 to 28 weeks and 63.6% at 29 to 32 weeks. The clearness rates of showing Sylvian fissure only on trans-thalamic section were 11.1% at 21 ∼ 24 weeks, 10.5% at 25 ∼ 28 weeks and 9.1% at 29 ∼ 32 weeks. The clearness rates of showing Sylvian fissure both on trans-cerebellar and trans-thalamic sections were 22.1% at 21 to 24 weeks, 15.0% at 25 to 28 weeks and 13.0% at 29 to 32 weeks. The unclearness rates of showing Sylvian fissure both on trans-cerebellar and trans-thalamic sections were 4.5%at 21 ∼ 24 weeks, 4.4% at 25 ∼ 28 weeks and 14.3% at 29 ∼ 32 weeks. The clearness rate of showing Sylvian fissure on trans-cerebellar section was significantly higher than on trans-thalamic section (P < 0.05). The total clearness rate of showing Sylvian fissure on trans-cerebellar section and trans-thalamic section were 83.1% and 28.3% respectively.
Conclusion In this study, it was suggested that prenatal ultrasound selection of trans-cerebellar section is better than trans-thalamic section in evaluating the developmental parameters related to the Sylvian fissure.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Construction of medical key disciplines in Shenzhen city, Grant/Award Number: SZXK051; Shenzhen Virtual Reality Clinical Application Public Service Platform enhancement project, Grant/Award Number: XMHT20190104001; Three Projects Funded Project in Shenzhen city, Grant/Award Number: SZSM201512026
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was approved by the Peking University Shenzhen Hospital and Health Service Human Research Ethics Committee. All pregnant women gave informed consent to this study.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
CONFLICT OF INTEREST The authors declare no potential conflict of interest
Funding information Construction of medical key disciplines in Shenzhen city, Grant/Award Number: SZXK051; Shenzhen Virtual Reality Clinical Application Public Service Platform enhancement project, Grant/Award Number: XMHT20190104001; Three Projects Funded Project in Shenzhen city, Grant/Award Number: SZSM201512026
DATA AVAILABILITY STATEMENT Data availability. The full data that supports the findings of this study are available from the corresponding author upon reasonable request.
Data Availability
Data availability. The full data that supports the findings of this study are available from the corresponding author upon reasonable request.