Abstract
Background Diagnosis of COVID-19 by PCR offers high sensitivity, but the utility of detecting samples with high cycle threshold (Ct) values remains controversial. Currently available rapid diagnostic tests (RDTs) for SARS-CoV-2 nucleocapsid antigens (Ag) have sensitivity well below PCR. The correlation of Ag and RNA quantities in clinical nasopharyngeal (NP) samples is unknown.
Methods An ultrasensitive, quantitative electrochemiluminescence immunoassay for SARS-CoV-2 nucleocapsid (the MSD® S-PLEX® CoV-2 N assay) was used to measure Ag in clinical NP samples from adults and children previously tested by PCR.
Results The S-PLEX Ag assay had a limit of detection (LOD) of 0.16 pg/mL and a cutoff of 0.32 pg/mL. Ag concentrations measured in clinical NP samples (collected in 3.0 mL media) ranged from less than 160 fg/mL to 2.7 ug/mL. Log-transformed Ag concentrations correlated tightly with Ct values. In 35 adult and 101 pediatric PCR-positive samples, sensitivity was 91% (95% CI, 77-98%) and 79% (70-87%), respectively. In samples with Ct ≤ 35, sensitivity was 100% (88-100%) and 96% (88-99%), respectively. In 50 adult and 40 pediatric PCR-negative specimens, specificity was 100% (93-100%) and 98% (87-100%), respectively.
Conclusions Nucleocapsid concentrations in clinical NP samples span 8 orders of magnitude and correlate closely with RNA concentrations (Ct values). The S-PLEX Ag assay had 96-100% sensitivity in samples from children and adults with Ct values ≤ 35, and 98-100% specificity. These results clarify Ag concentration distributions in clinical samples, providing insight into the performance of Ag RDTs and offering a new approach to diagnosis of COVID-19.
Key points SARS-CoV-2 nucleocapsid concentrations in clinical nasopharyngeal samples, measured with an ultrasensitive assay, spanned an 8-log range and correlated closely with PCR Ct values. The assay was 96-100% sensitive in pediatric/adult samples with Ct values ≤ 35, and 98-100% specific.
Competing Interest Statement
N.R.P., H.W., T.J.S., and R.L. do not have any conflicts of interest to declare. A.M., M.S. and G.S. are employees of MSD.
Funding Statement
The work at MSD was funded by MSD. The BCH team did not have dedicated funding for this study.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was performed under approval from the Boston Childrens Hospital IRB with waiver of informed consent.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data are available upon request