Background The COVID-19 pandemic has caused huge pressure on healthcare systems worldwide. Public health measures to control the virus are reliant on testing, including appropriate collection of specimens for analysis.
Methods A prospective study of nasopharyngeal swab technique by staff in an academic tertiary referral centre was carried out. Nasopharyngeal swab technique was evaluated by a novel design of a navigated swab on a three-dimensional model head.
Results Swab technique of 228 participants was assessed. Technique was poor, with a success rate of nasopharyngeal swabbing at 38.6%. Angle and length of insertion were significantly different between those with successful and unsuccessful technique. Doctors were significantly more accurate than nurses and non-healthcare professionals (p<0.01).
Conclusion Inaccurate specimen collection from poor swab technique could contribute to a false negative rate of testing for SARS-CoV-2. Specific training in nasopharyngeal anatomy and swab technique may improve the accuracy of nasopharyngeal swabbing.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
NA
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Beaumont Hospital clinical audit registration CA959
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Anonymous data available from research team. All data presented.