Abstract
Rapid diagnosis is critical for the treatment and prevention of diseases. In this research, we report sensing of antibodies specific to SARS-CoV-2 virus in seconds via an electrochemical platform consisting of gold micropillar array electrodes decorated with reduced graphene oxide and functionalized with recombinant viral antigens. The array electrodes are fabricated by Aerosol Jet (AJ) nanoparticle 3D printing, where gold nanoparticles (3-5nm) are assembled in 3D space, sintered, and integrated with a microfluidic device. The device is shown to detect antibodies to SARS-CoV-2 spike S1 protein and its receptor-binding-domain (RBD) at concentrations down to 1pM via electrochemical impedance spectroscopy and read by a smartphone-based user interface. In addition, the sensor can be regenerated within a minute by introducing a low-pH chemistry that elutes the antibodies from the antigens, allowing successive testing of multiple antibody samples using the same sensor. The detection time for the two antibodies tested in this work is 11.5 seconds. S1 protein sensing of its antibodies is specific, which cross-reacts neither with other antibodies nor with proteins such as Nucleocapsid antibody and Interleukin-6 protein. The proposed sensing platform is generic and can also be used for the rapid detection of biomarkers for other infectious agents such as Ebola, HIV, and Zika, which will benefit the public health.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external research funding was used for this research
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This is not a clinical study. No IRB was required for this study.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data needed to evaluate the conclusions in the paper are present in the paper and/or the Supplementary Materials. Additional data related to this paper may be requested from the authors.