Abstract
Continuously monitoring the Electrocardiogram (ECG) is an essential tool for Cardiovascular Disease (CVD) patients. In low-resource countries, the hospitals and health centers do not have adequate ECG systems, and this unavailability exacerbates the patients’ health condition. Lack of skilled physicians, limited availability of continuous ECG monitoring devices, and their high prices, all lead to a higher CVD burden in the developing countries. To address these challenges, we present a low-cost, low-power, and wireless ECG monitoring system with deep learning-based automatic arrhythmia detection. Flexible fabric-based design and the wearable nature of the device enhances the patient’s comfort while facilitating continuous monitoring. An AD8232 chip is used for the ECG Analog Front-End (AFE) with two 450 mi-Ah Li-ion batteries for powering the device. The acquired ECG signal can be transmitted to a smart-device over Bluetooth and subsequently sent to a cloud server for analysis. A 1-D Convolutional Neural Network (CNN) based deep learning model is developed that provides an accuracy of 94.03% in classifying abnormal cardiac rhythm on the MIT-BIH Arrhythmia Database.
Index Terms Wearable ECG, deep learning, arrhythmia detection.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was received.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
N/A
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data used in this research are open-sourced. References are provided in the manuscript.