Abstract
The use of computed tomography (CT) for the diagnostics of COVID-19 in the Russian Federation led to significant changes in the structure of X-ray diagnostics and levels of medical exposure of the patients. This study was aimed at the preliminary operative assessment of changes in the structure and collective dose from CT examinations in several representative hospitals, regions and on the level of the Russian Federation. The results of the study indicate that during the transformation of hospitals from general medical practice into dedicated COVID-19 facilities, the number of CT examinations increased up to 30%; the collective dose from CT exams increased up to a factor of 1.5. During a partial transformation of a medical facility into the hospital with separate COVID-19 departments, the increase in the number of CT examinations in the facility was more significant (up to a factor of 2 or more). These numbers correspond to 1.5 - 2.5 chest CT examinations (from 1 to 6) per patient admitted to hospital with COVID-19 diagnosis; and 1.2 chest CT examinations per patient in outpatient facilities, including a mandatory CT scan for the staging of COVID-19. The collective dose from CT examinations in the Russian Federation for March-June period of 2020 increased by the factor of 2 (from 16k man-Sv to 32k man-Sv); the collective dose of COVID-19 patients was about 12k man-Sv. For a more detailed and reliable assessment of the dynamics of changes in the structure of diagnostic radiology and levels of radiation exposure of patients in the Russian Federation, data collection in the regions of the Russian Federation and individual medical facilities will continue.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The authors declare that this study has not been externally funded.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was approved by the IRB of the St-Petersburg Research Institute of Radiation Hygiene after prof. P.V. Ramzaev
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All the data usied in the preparation of the manuscript is available by request from the authors.