ABSTRACT
The COVID-19 pandemic caused by severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) has overwhelmed health systems worldwide and highlighted limitations of diagnostic testing. Several types of diagnostics including RT-PCR-based assays, antigen detection by lateral flow assays and antibody-based assays have been developed and deployed in a short time. However, many of these assays are lacking in sensitivity and/or specificity. Here, we describe an immunoaffinity purification followed by high resolution mass spectrometry-based targeted assay capable of detecting viral antigen in nasopharyngeal swab samples of SARS-CoV-2 infected individuals. Based on our discovery experiments using purified virus, recombinant viral protein and nasopharyngeal swab samples from COVID-19 positive patients, nucleocapsid protein was selected as a target antigen. We then developed an automated antibody capture-based workflow coupled to targeted high-field asymmetric ion mobility spectrometry (FAIMS) - parallel reaction monitoring (PRM) assays on an Orbitrap Exploris 480 mass spectrometer. An ensemble machine learning-based model for determining COVID-19 positive samples was created using fragment ion intensities in the PRM data. This resulted in 97.8% sensitivity and 100% specificity with RT-PCR-based molecular testing as the gold standard. Our results demonstrate that direct detection of infectious agents from clinical samples by mass spectrometry-based assays have potential to be deployed as diagnostic assays in clinical laboratories.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The following reagent was deposited by the Centers for Disease Control and Prevention and obtained through BEI Resources, NIAID, NIH: SARS-Related Coronavirus 2, Isolate USA-WA1/2020, Gamma-Irradiated, NR-52287. This study was supported by 'DBT/Wellcome Trust India Alliance' Margdarshi Fellowship grant IA/M/15/1/502023 awarded to AP.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
IRB, Mayo Clinic, Rochester, MN
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The mass spectrometry proteomics data have been deposited to the ProteomeXchange Consortium via the PRIDE partner repository with the dataset identifier PXD020644. Reviewer account details: Username: reviewer94766{at}ebi.ac.uk Password: J8setKN6