Abstract
SARS-CoV-2 control in the United States is hampered by limited testing capacity. We evaluated a simple, outdoor, mobile RT-LAMP assay workflow where self-collected saliva is tested for SARS-CoV-2 RNA. 195 volunteers were tested over 8 days. Testing results were 100% concordant with qRT-PCR, with all but one person testing SARS-CoV-2-negative.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was made possible by financial support through NIH Rapid Acceleration of Diagnostics (contract number pending). Additional funding was provided by both Wisconsin National Primate Research Center (WNPRC) and from Wisconsin Alumni Research Foundation COVID-19 Challenge.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This work was performed under approved UW-Madison Health Sciences IRB Protocol #2020-0855.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data and protocols are available at https://openresearch.labkey.com/wiki/Coven/page.view?name=field-testing