Abstract
COVID-19 can exponentially precipitate life-threatening emergencies as witnessed during the recent spreading of a novel coronavirus infection which can rapidly evolve into lung collapse and respiratory distress (among other various severe clinical conditions). Our study evaluates the performance of a tailor-designed deep convolutional network on the tasks of early detection and localization of radiological signs associated to COVID-19 on frontal chest X-rays. We also asses the framework’s capacity in differentiating the above-mentioned signs, which are usually confused with the more usual common bacterial and viral pneumonias. Open-source chest X-ray images categorized as Normal, Non-COVID-19 and COVID-19 pneumonias were downloaded from the NIH (n=2,259), RSNA (n=600) and HM Hospitales (n=2,307). Our algorithmic framework was able to precisely detect the images with COVID19-related radiological findings (mean Accuracy: 90.5%; Sensitivity: 80.6%; Specificity: 98.0%), whilst correctly categorizing images deemed as Non-COVID-19 pneumonias (mean Accuracy: 88.4%; Sensitivity: 93.3%; Specificity: 92.0%) and normal chest X-rays (mean Accuracy 92.1%; Sensitivity: 91.8%; Specificity: 94.3%). The associated results show that our AI framework is able to classify COVID-19 accurately, making of it a potential tool to improve the diagnostic performance across primary-care centres and, to grant priority to a subset of algorithmic selected images for urgent follow-on expert review. This would sensibly accelerate diagnosis in remote locations, reduce the bottleneck on specialized centres, and/or help to alleviate the needs on situations of scarcity in the availability of molecular tests.
Competing Interest Statement
Maximiliano Lucius and Carlos M. Galmarini are employees of Topazium
Funding Statement
No external funding was received
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
In this work, we have use from the public datasets from HM Hospitales, NIH and RSNA. The former dataset should be requested to HM Hospitales. The NIH and RSNA can be downloaded from the links provided in the Ms.