ABSTRACT
Background Spontaneous echo contrast(SEC) is an echocardiographic finding particularly found in left atrium of patients with mitral stenosis and known as a risk factor for stroke. However, its pathophysiology is not fully understood.
Material and Method Forty-eight patients with mitral stenosis scheluded for percutaneous mitral valvuloplasty were included in the study. SEC was graded from 0 to 4 according to its density. Blood samples were taken from the aorta and left atrium during the procedure. Whole blood viscosity, plasma viscosity(PV) and peripheral blood smears were obtained and analysed separately from these sites. Prior to the procedure, all participants also underwent transthoracic and transesophageal echocardiography.
Results Severe SEC(grade 3-4) was found in 23 patients(48%), remaining 25 patients(52%) had mild to moderate SEC(grade 0-1-2). The patients with atrial fibrillation(AF) and hypertension(HT) had more significantly severe SEC compared to other patients. Compared to patients with mild to moderate SEC, patients with severe SEC had increased age, body mass index, left atrial diameter, left atrial area and left atrial PV. However, ejection fraction, left atrial appendage(LAA) filling and emptying velocities, LAA lateral wall late systolic velocity, LAA fractional area change and pulmonary vein(PVe) systolic velocity were found to be significantly reduced in patients with severe SEC compared to mild to moderate SEC. On multiple linear regression analysis, AF, left atrium PV and left atrial diameter were the strongly correlated with SEC grade.
Conclusion We have shown that AF, HT, systolic dysfunction of LAA, increased left atrial dimensions, reduced ejection fraction, decreased PVe flow velocity and increased left atrial PV were related with the development of SEC in patients with mitral stenosis.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Baskent University
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data are available upon reasonable request