ABSTRACT
Aim This study aims to identify the normative values of handgrip strength for Portuguese workers in the automotive industry.
Methods About 1225 employees were invited to participate in the study. The final sample consisted of 656 employees in the assembly area. The handgrip strength was measured in kilograms (kg) using the Jamar digital dynamometer. Two measurements were performed in both hands, totaling four measurements. For the present study, the maximum value was recorded regardless of the hand.
Results showed the peak mean values of handgrip strength in the group of women was 34 kg in the age group of 35-39 years, and the group of men the peak mean was 52 kg in the age group of 25-34 years. The most pronounced decline in the female group appears in the age of 30-34 years with 30 kg and the men group the decline occurs of 2kg below the peak force, in the age group between the 40-57 years. This study used a cut-off at 2 SD below by the sex-specific peak mean.
Conclusion Normative values can help delineate the career path of workers because they portray risk values according to age, height, and gender. And they can also help in adjusting the morphological and strength characteristics of the worker with the task to be performed, as an example of work above head level.
Key Messages
The handgrip strength is a general indicator of muscle strength, in addition to being closely related to cardiovascular and nutritional diseases. Also, this measure is one of the keys to defining sarcopenia.
One of the main findings of the study was found in the group of women aged 30-34 years, with a significant decline in handgrip strength compared to other age groups. Furthermore, the present study, established for the first time, normative values for the handgrip strength of Portuguese workers in the automotive industry.
The handgrip strength decline is a crucial predictor of frailty syndrome, and sarcopenia can be checked by the occupational medicine department, individually, by the risk threshold outcomes presents in this study. Also, it is possible to design the conditions work processes associated with the predictive values of HG2 and HG5 and the implementation of the workers’ clinical surveillance system through periodic tests of handgrip strength.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Coordination of Superior Level Staff Improvement(CAPES, Brasil).
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Relevant data is exposed in the article and complementary data will be available for support.