Abstract
Aims To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism.
Methods 31 eyes of 31 patients who underwent cataract surgery with toric intraocular lens implantation were included. All patients had corneal opacity with regular astigmatism. Preoperative total corneal astigmatism was determined considering posterior astigmatism using a rotating Scheimpflug camera (Pentacam®: Oculus, Wetzlar, Germany). At 2 months after toric intraocular lens implantation, we evaluated residual astigmatism, uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA).
Results Postoperative UCVA and BCVA (0.30 ± 0.17, 0.22 ± 0.16LogMAR) statistically improved compared to preoperative UCVA and BCVA (1.2 ± 0.34, 1.1 ± 0.30LogMAR, respectively) (P<0.01). Postoperative residual refractive astigmatism (1.2 ± 0.35D) was statistically reduced compared to preoperative refractive astigmatism (2.4 ± 0.65D) (P<0.05). Preoperative and postoperative total corneal astigmatism values were not statistically different. All cases achieved visual acuity were as good as or better than that preoperatively. The percentage of corneal opacity covering pupillary area had significant negative correlation with postoperative UCVA and BCVA (logMAR) (R=-0.88 P<0.00001 and R=-0.87 P<0.00001, respectively)
Conclusion Toric intraocular lens implantation can improve UCVA, BCVA, and refractive astigmatism in cataract patient with corneal opacity. The percentage of central corneal opacity covering pupillary area is the major prognostic factor for postoperative visual improvement. Therefore, toric intraocular lens implantation should be considered for cataract patients who have corneal opacity with high astigmatism.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2018R1D1A1A02085334 & 2016R1A6A1A03010528)
Author Declarations
All relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
Any clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.
Not Applicable
I have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.
Yes
Footnotes
The authors do not have any conflicts of interest or proprietary interests in the contents of this manuscript.
This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2018R1D1A1A02085334 & 2016R1A6A1A03010528)
Data Availability
All data relevant to the study are included in the article or uploaded as supplementary information
Data Availability
All data relevant to the study are included in the article or uploaded as supplementary information