Abstract
Self-contamination during doffing of personal protective equipment (PPE) is a concern for healthcare workers (HCW) following SARS-CoV-2 positive patient care. Staff may subconsciously become contaminated through improper glove removal, so quantifying this risk is critical for safe working procedures. HCW surface contact sequences on a respiratory ward were modelled using a discrete-time Markov chin for: IV-drip care, blood pressure monitoring and doctors’ rounds. Accretion of viral RNA on gloves during care was modelled using a stochastic recurrence relation. The HCW then doffed PPE and contaminated themselves in a fraction of cases based on increasing case load. The risk of infection from this exposure was quantified using a dose-response methodology. A parametric study was conducted to analyse the effect of: 1a) increasing patient numbers on the ward, 1b) the proportion of COVID-19 cases, 2) the length of a shift and 3) the probability of touching contaminated PPE. The driving factors for infection risk were surface contamination and number of surface contacts. HCWs on a 100% COVID-19 ward were less than 2-fold more at risk than on a 50% COVID ward (1.6% vs 1%), whilst on a 5% COVID-19 ward, the risk dropped to 0.1% per shift (sd=0.6%). IV-drip care resulted in higher risk than blood pressure monitoring (1.1% vs 1% p<0.0001), whilst doctors’ rounds produced a 0.6% risk (sd=0.8%). Recommendations include supervised PPE doffing procedures such as the “doffing buddy” scheme, maximising hand hygiene compliance post-doffing and targeted surface cleaning for surfaces away from the patient vicinity.
Importance Infection risk from self-contamination during doffing PPE is an important concern in healthcare settings, especially on a COVID-19 ward. Fatigue during high workload shifts may result in increased frequency of mistakes and hence risk of exposure. Length of staff shift and number of COVID-19 patients on a ward correlate positively with the risk to staff through self-contamination after doffing. Cleaning of far-patient surfaces is equally important as cleaning traditional “high-touch surfaces”, given that there is an additional risk from bioaerosol deposition outside the patient zone(1).
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This research is funded by the Engineering and Physical Sciences Research Council, UK: Healthcare Environment Control, Optimisation and Infection Risk Assessment (https://HECOIRA.leeds.ac.uk) (EP/P023312/1). M. Lopez-Garcia was funded by the Medical Research Council, UK (MR/N014855/1). J. Proctor was funded by EPSRC Centre for Doctoral Training in Fluid Dynamics at Leeds (EP/L01615X/1).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethical approval for the study was given by the NHS Health Research Authority Research Ethics Committee (London - Queen Square Research Ethics Committee), REF: 19/LO/0301.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Under a Creative Commons Zero v1.0 Universal license (CC-BY), code can be accessed at: https://github.com/awilson12/surface-contam-model-COVID19