Abstract
Objective The meniscus tear is a common problem in sports trauma. The imaging diagnosis mainly depends on the MRI. To improve the diagnostic accuracy and efficiency, a deep learning model was employed in this study and the identification efficiency has been evaluated.
Methods The standard knee MRI images of 924 individual patients were used to complete the training, validation, and testing process. The Mask R-CNN was considered as the deep learning network structure, and the ResNet50 was considered as the backbone network. The deep learning model was trained and validated with a dataset containing 504 and 220 patients, respectively. The accuracy testing was performed on a dataset of 200 patients and reviewed by an experienced radiologist and a sports medicine physician.
Results After training and validation, the deep learning model effectively recognized the healthy and injured meniscus. The overall average precision of the bounding box and pixel mask was more than 88% when the IoU threshold value was 0.75. The detailed average precision of three types of menisci (healthy, torn, and degenerated) was ranged from 68% to 80%. The overall sensitivity of the bounding box and pixel mask was more than 74% at the IoU threshold from 0.50 to 0.95. The diagnosis accuracy for the healthy, torn, and degenerated meniscus was 87.50%, 86.96%, and 84.78%, respectively.
Conclusion The Mask R-CNN recognized effectively and predicted the meniscus injury, especially for the tears that occurred at different parts of the meniscus. The recognition accuracy was admirable. The diagnostic accuracy can be further improved with the increase of the training sample size. Therefore, this tool has great potential in the application for the diagnosis of meniscus injury.
The translational potential of this article Deep learning model has unique effect in reducing doctors’ workload and improving diagnosis accuracy. It can identify and classify injured and healthy meniscus more accurately after training and learning datasets. The torn and degenerated meniscus can also be distinguished by this model. This technology could serve as an effective tool for clinical MRI-assisted diagnostics in meniscus injury.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study was supported by the Natural Science Foundation of Jiangsu Province (BK20200121), China Postdoctoral Science Foundation (2020M671454), National Natural Science Foundation of China (81730067, 51575100), Nanjing Science and Technology Development Project (201803026).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The studies followed relevant guidelines, and had approval from the ethics committee of Drum Tower Hospital affiliated to the Medical School of Nanjing University.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors
Abbreviations
- MRI
- magnetic resonance imaging
- SE T1WI
- spin-echo T1 weighted image
- FSE T2WI
- fast spin-echo T2 weighted image
- FS FSE PDWI
- fat-suppressed fast spin-echo proton density-weighted image
- GRE
- gradient echo
- AI
- artificial intelligence
- PDW
- proton density-weighted
- CA
- cartilage tissue
- AT
- anterior horn tear
- PT
- posterior horn tear
- MBT
- meniscus body tear
- AD
- anterior horn degeneration
- PD
- posterior horn degeneration
- MBD
- meniscus body degeneration
- AH
- anterior horn health
- PH
- posterior horn health
- MBH
- meniscus body health
- RPN
- region proposal network
- ROI
- region of interest
- TP
- true positive
- FP
- false positive
- FN
- false negative
- AP
- average precision
- IoU
- intersection over union