ABSTRACT
Accurate assessment of the jugular venous pressure (JVP) and right atrial pressure (RAP) has relied on the same bedside examination method since 1930. While this technique provides a rough estimate of right sided pressures, it is limited by poor sensitivity and overall diagnostic inaccuracy. The internal jugular vein (IJV) is difficult to visualize in many patients and relies on an incorrect assumption that the right atrium lies 5 centimeters below the sternum. Point-of-care ultrasound (POCUS) offers an alternative method for more precisely estimating JVP and RAP. We propose a novel method of measuring the right atrial depth (RAD) using a sonographic measurement of the depth of the posterior left ventricular outflow tract as a surrogate landmark to the center of the right atrium when viewed in the parasternal long axis view. This is combined with determination if JVD was present at the supraclavicular point. Sensitivity, specificity, PPV, NPV of JVD at the supraclavicular point was 70%, 76%, 59%, 91% respectively. These values were confounded by the lack of standardization of zero reference landmarks (ZRLs) used during the right heart catheterizations. When the RAD measurement was adjusted to account for measurement error the sensitivity of JVD at supraclavicular point for elevated RAP improved to 90% with negative predictive value of 96%. This may offer a rapid and reliable method for ruling out elevated RAP and increase objectivity in our volume status assessment.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics committee/IRB of Inova Fairfax Hospital gave ethical approval for this work
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors