Background Isothermal amplification-based tests were developed as rapid, low-cost, and simple alternatives to real-time reverse transcriptase-polymerase chain reaction (RT-PCR) tests for SARS-COV-2 detection.
Methods Clinical performance of two isothermal amplification-based tests (Atila Biosystems iAMP COVID-19 detection test and OptiGene COVID-19 Direct Plus RT-LAMP test) was compared to clinical RT-PCR assays using different sampling strategies. A total of 1378 participants were tested across four study sites.
Results Compared to standard of care RT-PCR testing, the overall sensitivity and specificity of the Atila iAMP test for detection of SARS-CoV-2 were 76.2% and 94.9%, respectively, and increased to 88.8% and 89.5%, respectively, after exclusion of an outlier study site. Sensitivity varied based on the anatomic collected site. Sensitivity for nasopharyngeal was 65.4% (range across study sites:52.8%-79.8%), mid-turbinate 88.2%, saliva 55.1% (range across study sites:42.9%-77.8%) and anterior nares 66.7% (range across study sites:63.6%-76.5%). The specificity for these anatomic collection sites ranged from 96.7% to 100%. Sensitivity improved in symptomatic patients (overall 82.7%) and those with a higher viral load (overall 92.4% for ct≤25). Sensitivity and specificity of the OptiGene Direct Plus RT-LAMP test, conducted at a single study-site, were 25.5% and 100%, respectively.
Conclusions The Atila iAMP COVID test with mid-turbinate sampling is a rapid, low-cost assay for detecting SARS-COV-2, especially in symptomatic patients and those with a high viral load, and could be used to reduce the risk of SARS-COV-2 transmission in clinical settings. Variation of performance between study sites highlights the need for site-specific clinical validation of these assays before clinical adoption.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
NA
Funding Statement
The research was funded by the intramural NCI Cancer MoonshotSM and intramural research program.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study was approved by the ethical review board of Comite Nacional de Etica de Investigacion en Salud (IRB no FWA00010986) in El Salvador, Comite de Etica, Instituto de Investigaciones en Ciencias de la Salud, Universida Nacional de Asucion (IRB no P37 2020) in Paraguay, MCW IRB (IRB no FWA00000820) in Wisconsin, and the Newark Health Sciences IRB for Rutgers Biomedical Health Sciences (IRB no. Pro2020001801) in New Jersey.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The datasets used in the current study are available from the corresponding author on reasonable request.
Abbreviations
- CI
- Confidence Interval
- COVID-19
- Coronavirus Disease of 2019
- CT
- Cycle Threshold
- EUA
- Emergency Use Authorization
- iAMP
- Isothermal Amplification
- IFU
- Instruction for Use
- LAMP
- Loop-mediated Isothermal Amplification
- LMIC
- Low- and Middle-Income Countries
- LOD
- Limit of Detection
- MCW
- Medical College of Wisconsin
- NAAT
- Nucleic Acid Amplification Test
- NP
- Nasopharyngeal
- OP
- Oropharyngeal
- NJMS
- Rutgers New Jersey Medical School
- RT-PCR
- Reverse Transcription-Polymerase Chain Reaction
- SARS-COV-2
- Severe Acute Respiratory Syndrome Coronavirus 2
- SPSS
- Statistical Package of Social Studies
- VTM
- Viral Transport Medium