Abstract
Rapid antigen-detecting tests (Ag-RDTs) can complement molecular diagnostics for COVID-19. The recommended temperature for storage of SARS-CoV-2 Ag-RDTs ranges between 5-30°C. In many countries that would benefit from SARS-CoV-2 Ag-RDTs, mean temperatures exceed 30°C. We assessed analytical sensitivity and specificity of eleven commercially available SARS-CoV-2 Ag-RDTs using different storage and operational temperatures, including (i) long-term storage and testing at recommended conditions, (ii) recommended storage conditions followed by 10 minutes exposure to 37°C and testing at 37°C and (iii) 3 weeks storage followed by testing at 37°C. The limits of detection of SARS-CoV-2 Ag-RDTs under recommended conditions ranged from 8.2×105-7.9×107 genome copies/ml of infectious SARS-CoV-2 cell culture supernatant. Despite long-term storage at recommended conditions, 10 minutes pre-incubation of Ag-RDTs and testing at 37°C resulted in about ten-fold reduced sensitivity for 46% of SARS-CoV-2 Ag-RDTs, including both Ag-RDTs currently listed for emergency use by the World Health Organization. After 3 weeks of storage at 37°C, 73% of SARS-CoV-2 Ag-RDTs exhibited about ten-fold reduced sensitivity. Specificity of SARS-CoV-2 Ag-RDTs using cell culture-derived human coronaviruses HCoV-229E and HCoV-OC43 was not affected by storage and testing at 37°C. In summary, short- and long-term exposure to elevated temperatures likely impairs sensitivity of several SARS-CoV-2 Ag-RDTs that may translate to false-negative test results at clinically relevant virus concentrations compatible with inter-individual transmission. Ensuring appropriate transport and storage conditions, and development of tests that are more robust across temperature fluctuations will be important for accurate use of SARS-CoV-2 Ag-RDTs in tropical settings.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study is based on research funded in part by the Bill & Melinda Gates Foundation (grant ID INV-005971). The findings and conclusions contained within are those of the authors and do not necessarily reflect positions or policies of the Bill & Melinda Gates Foundation. The study was further supported in part by the Foundation for Innovative New Diagnostics (FIND), including procurement of some test kits.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
No IRB and/or ethics committee approvals were required for this study.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All relevant data are within the manuscript and its Supporting Information files.