Ambient mass spectrometry

RG Cooks, Z Ouyang, Z Takats, JM Wiseman - Science, 2006 - science.org
… Even minor components can be identified by recording their MS/MS spectra; for example,
the isolation of the ion with m/z = 214 and the measurement of its product spectrum allows its …

Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biology

Z Takats, JM Wiseman… - Journal of mass …, 2005 - Wiley Online Library
… Ions at m/z 906 and 936 correspond to the sodiated molecules of each compound. (b)
Positive-ion DESI spectrum of 10-ng equine cytochrome c deposited on a PMMA surface. …

Metabolic phenotyping in clinical and surgical environments

…, E Holmes, JM Kinross, AW Darzi, Z Takats… - Nature, 2012 - nature.com
Metabolic phenotyping involves the comprehensive analysis of biological fluids or tissue
samples. This analysis allows biochemical classification of a person's physiological or …

Mass spectrometry sampling under ambient conditions with desorption electrospray ionization

Z Takats, JM Wiseman, B Gologan, RG Cooks - Science, 2004 - science.org
… -counter antihistamine Loratadine (m/z 383/385). Other peaks, eg, at m/z 245, are either due
to … assignments are from the instrument data system and are accurate to just 0.5 m/z units. …

[PDF][PDF] SARS-CoV-2 Omicron-B. 1.1. 529 leads to widespread escape from neutralizing antibody responses

…, D Stuart, C Summers, OV Swann, Z Takats… - Cell, 2022 - cell.com
… Trust (grant 090532/Z/09/Z). The computational aspects of this research were supported by
the Wellcome Trust Core award grant number 203141/Z/16/Z and the NIHR Oxford BRC. We …

Intraoperative tissue identification using rapid evaporative ionization mass spectrometry

…, A Darzi, JK Nicholson, Z Takáts - Science translational …, 2013 - science.org
… , m/z 673.48 was a characteristic peak of alveolar lung tissue representing PA(34:1)-H; m/z
:1)-NH 3 ; whereas m/z 697.48 and m/z 885.55 were peaks found in all three healthy tissues, …

Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry

Z Takáts, I Cotte-Rodriguez, N Talaty, H Chen… - Chemical …, 2005 - pubs.rsc.org
… The corresponding MS/MS product ion spectrum of the molecular radical anion, m/z 227, is
shown in the inset. … Besides (M + H) + ions, ionic species 14 and 28 higher in m/z ratio were …

Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment

H Chen, NN Talaty, Z Takáts, RG Cooks - Analytical chemistry, 2005 - ACS Publications
… m/z 203 peak yields the peak at m/z 161, a characteristic elimination of ketene. The peak at
m/z … , and the minor peak at m/z 175 is due to a loss of 28, probably CO from the ion m/z 203. …

Electrosonic spray ionization. A gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion− molecule reactions at …

Z Takáts, JM Wiseman, B Gologan… - Analytical chemistry, 2004 - ACS Publications
Electrosonic spray ionization (ESSI), a variant on electrospray ionization (ESI), employs a
traditional micro ESI source with supersonic nebulizing gas. The high linear velocity of the …

Identification of biological tissues by rapid evaporative ionization mass spectrometry

…, L Balogh, L Sasi-Szabo, M Toth, Z Takats - Analytical …, 2010 - ACS Publications
… , in the mass range 600−900 m/z, unless otherwise stated. Spectral data was reduced using
a 1 m/z bin size in the case of the QIT data and a 0.01 m/z bin size in the case of the Orbitrap …