RT Journal Article SR Electronic T1 Flushing of stagnant premise water systems after the COVID-19 shutdown can reduce infection risk by Legionella and Mycobacterium spp JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.09.14.20194407 DO 10.1101/2020.09.14.20194407 A1 Hozalski, Raymond M. A1 LaPara, Timothy M. A1 Zhao, Xiaotian A1 Kim, Taegyu A1 Waak, Michael B. A1 Burch, Tucker A1 McCarty, Michael YR 2020 UL http://medrxiv.org/content/early/2020/09/15/2020.09.14.20194407.abstract AB The unprecedented widespread closing of buildings due to the COVID-19 pandemic has allowed water to stagnate in premise plumbing systems, creating conditions that may facilitate the growth of opportunistic pathogens. In this study, we flushed and collected samples from showers in buildings that had been unoccupied for approximately two months and quantified Legionella pneumophila using a commercial cultivation-based assay. In addition, all bacteria, Legionella spp., L. pneumophila, L. pneumophila serogroup 1, non-tuberculous mycobacteria (NTM), and Mycobacterium avium complex (MAC) were analyzed using quantitative PCR (qPCR). Despite low or negligible total chlorine in the stagnant pre-flush water samples, L. pneumophila were not detected by either method; Legionella spp., NTM, and MAC, however, were widespread. Using quantitative microbial risk assessment (QMRA), estimated risks of clinical illness from exposure to legionella and MAC via showering were generally low, but the risk of subclinical infection via Legionella spp. could exceed a 10-7 daily risk threshold if just a small fraction (≥0.1 %) of those legionellae detected by qPCR are highly infectious. Flushing cold and hot water lines rapidly restored a total chlorine (as chloramine) residual and decreased all bacterial gene targets to building inlet water levels within 30 min. Following flushing, the chlorine residual rapidly dissipated and bacterial gene targets rebounded, approaching pre-flush concentrations after 6 to 7 days of stagnation. These results suggest that stagnant water in premise plumbing may contain elevated levels of opportunistic pathogens; flushing, however, can rapidly improve water quality and reduce the health risk but the improvement will be short-lived if building disuse persists.Competing Interest StatementThe authors have declared no competing interest.Funding StatementMinnesota Department of HealthAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:No IRB oversight needed as no sampling or testing of humans was done.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData are provided in the manuscript or supporting information file.